Laypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin

نویسندگان

  • Gereon Schälte
  • Christian Stoppe
  • Meral Aktas
  • Mark Coburn
  • Steffen Rex
  • Marlon Schwarz
  • Rolf Rossaint
  • Norbert Zoremba
چکیده

INTRODUCTION Supraglottic airway devices have frequently been shown to facilitate airway management and are implemented in the ILCOR resuscitation algorithm. Limited data exists concerning laypersons without any medical or paramedical background. We hypothesized that even laymen would be able to operate supraglottic airway devices after a brief training session. METHODS Four different supraglottic airway devices: Laryngeal Mask Classic (LMA), Laryngeal Tube (LT), Intubating Laryngeal Mask (FT) and CobraPLA (Cobra) were tested in 141 volunteers recruited in a technical university cafeteria and in a shopping mall. All volunteers received a brief standardized training session. Primary endpoint was the time required to definitive insertion. In a short questionnaire applicants were asked to assess the devices and to answer some general questions about BLS. RESULTS The longest time to insertion was observed for Cobra (31.9 ± 27.9 s, range: 9-120, p < 0.0001; all means ± standard deviation). There was no significant difference between the insertion times of the other three devices. Fewest insertion attempts were needed for the FT (1.07 ± 0.26), followed by the LMA (1.23 ± 0.52, p > 0.05), the LT (1.36 ± 0.61, p < 0.05) and the Cobra (1.45 ± 0.7, p < 0.0001). Ventilation was achieved on the first attempt significantly more often with the FT (p < 0.001) compared to the other devices. Nearly 90% of the participants were in favor of implementing supraglottic airway devices in first aid algorithms and classes. CONCLUSION Laypersons are able to operate supraglottic airway devices in manikin with minimal instruction. Ventilation was achieved with all devices tested after a reasonable time and with a high success rate of > 95%. The use of supraglottic airway devices in first aid and BLS algorithms should be considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices.

We evaluated the performance of four currently available manikins: Airway Management Trainer (Ambu, UK), Airway Trainer (Laerdal, Norway), Airsim (Trucorp, Ireland), 'Bill 1' (VBM, Germany), with eight supraglottic airway devices: Airway Management Device, Cobra Perilaryngeal Airway, Combitube, i-Gel, Laryngeal Tube, Laryngeal Tube Disposable, Laryngeal Tube Suction II and Streamlined Liner of ...

متن کامل

Does a 4 diagram manual enable laypersons to operate the laryngeal mask supreme®? A pilot study in the manikin

BACKGROUND Bystander resuscitation plays an important role in lifesaving cardiopulmonary resuscitation (CPR). A significant reduction in the "no-flow-time", quantitatively better chest compressions and an improved quality of ventilation can be demonstrated during CPR using supraglottic airway devices (SADs). Previous studies have demonstrated the ability of inexperienced persons to operate SADs...

متن کامل

Airway management in simulated restricted access to a patient - can manikin-based studies provide relevant data?

BACKGROUND Alternatives to endotracheal intubation (ETI) are required when access to the cranial end of the patient is restricted. In this study, the success rate and time duration of standard intubation techniques were compared with two different supraglottic devices. Two different manikins were used for the study, and the training effect was studied when the same manikin was repeatedly used. ...

متن کامل

A Comparison of Three Different Supraglottic Airway Devices in Neonatal Airway Training during Resuscitation Simulation

Objective: The aim of this study was to compare the success rates for insertion using the laryngeal mask, laryngeal tube, and I-gel supraglottic airway devices in a neonatal airway manikin during a resuscitation simulation course. Methods: Three groups of health care professionals were given a brief supervised training in using the devices. For each participant the positioning of each device wa...

متن کامل

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2011