BACKGROUND AND PURPOSE We have developed PC HYPRFlow, a comprehensive MRA technique that includes a whole-brain CE dynamic series followed by PC velocity-encoding, yielding a time series of high-resolution morphologic angiograms with associated velocity information. In this study, we present velocity data acquired by using the PC component of PC HYPRFlow (PC-VIPR). MATERIALS AND METHODS Ten healthy volunteers (6 women, 4 men) were scanned by using PC HYPRFlow and 2D-PC imaging, immediately followed by velocity measurements by using TCD. Velocity measurements were made in the M1 segments of the MCAs from the PC-VIPR, 2D-PC, and TCD examinations. RESULTS PC-VIPR showed approximately 30% lower mean velocity compared with TCD, consistent with other comparisons of TCD with PC-MRA. The correlation with TCD was r = 0.793, and the correlation of PC-VIPR with 2D-PC was r = 0.723. CONCLUSIONS PC-VIPR is a technique capable of acquiring high-resolution MRA of diagnostic quality with velocity data comparable with TCD and 2D-PC. The combination of velocity information and fast high-resolution whole-brain morphologic angiograms makes PC HYPRFlow an attractive alternative to current MRA methods.
منابع مشابه
Changes in blood flow velocity and diameter of the middle cerebral artery during hyperventilation: assessment with MR and transcranial Doppler sonography.
PURPOSE To compare blood flow velocity changes within the middle cerebral artery (MCA) during hyperventilation, as measured with by both transcranial Doppler sonography and MR imaging, with the diameter of the MCA as measured with MR imaging alone. METHODS The studies were performed in six healthy volunteers ranging in age from 22 to 31 years (mean, 27 years). Transcranial Doppler sonography ...
متن کاملBlood-flow volume quantification in internal carotid and vertebral arteries: comparison of 3 different ultrasound techniques with phase-contrast MR imaging.
BACKGROUND AND PURPOSE Optimal estimation of cerebral blood-flow volume (BFV) may be an important indicator for better evaluation of the patients with cerebrovascular disorders. In this study, we compared the BFV values at bilateral internal carotid and vertebral arteries of healthy volunteers obtained with color Doppler, power Doppler, and B-flow ultrasound (US) studies and tried to determine ...
متن کاملTranscranial doppler sonography diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine
Background: An imbalance of the cerebrovascular response during functional activation of the brain has been postulated as a factor in the pathophysiology of migraine. The purpose of this study was to determine the transcranial doppler sonography (TDS) diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine. Methods: This study was carried out on 46 pa...
متن کاملBlood flow in major cerebral arteries measured by phase-contrast cine MR.
PURPOSE To measure mean blood flow in individual cerebral arteries (carotid, basilar, anterior cerebral, middle cerebral, and posterior cerebral) using a cine phase contrast MR pulse sequence. METHODS Ten healthy volunteers (22 to 38 years of age) were studied. The cine phase-contrast section was positioned perpendicular to the vessel of interest using oblique scanning planes. This pulse sequ...
متن کاملAssessment of intracranial blood flow velocities using a computer controlled vasoactive stimulus: a comparison between phase contrast magnetic resonance angiography and transcranial Doppler ultrasonography.
PURPOSE To compare measurements of blood flow velocity (BFV) and BFV changes in the middle cerebral arteries (MCA) acquired from phase contrast magnetic resonance angiography (PCMRA) and transcranial Doppler ultrasound (TCD) during controlled manipulation of end-tidal partial pressure of carbon dioxide (PetCO2 ). MATERIALS AND METHODS In vivo TCD and PCMRA velocity data from the M1 segment in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 32 1 شماره
صفحات -