Off-resonance artifacts correction with convolution in k-space (ORACLE).
نویسندگان
چکیده
Off-resonance artifacts hinder the wider applicability of echo-planar imaging and non-Cartesian MRI methods such as radial and spiral. In this work, a general and rapid method is proposed for off-resonance artifacts correction based on data convolution in k-space. The acquired k-space is divided into multiple segments based on their acquisition times. Off-resonance-induced artifact within each segment is removed by applying a convolution kernel, which is the Fourier transform of an off-resonance correcting spatial phase modulation term. The field map is determined from the inverse Fourier transform of a basis kernel, which is calibrated from data fitting in k-space. The technique was demonstrated in phantom and in vivo studies for radial, spiral and echo-planar imaging datasets. For radial acquisitions, the proposed method allows the self-calibration of the field map from the imaging data, when an alternating view-angle ordering scheme is used. An additional advantage for off-resonance artifacts correction based on data convolution in k-space is the reusability of convolution kernels to images acquired with the same sequence but different contrasts.
منابع مشابه
Accelerating Magnetic Resonance Imaging through Compressed Sensing Theory in the Direction space-k
Magnetic Resonance Imaging (MRI) is a noninvasive imaging method widely used in medical diagnosis. Data in MRI are obtained line-by-line within the K-space, where there are usually a great number of such lines. For this reason, magnetic resonance imaging is slow. MRI can be accelerated through several methods such as parallel imaging and compressed sensing, where a fraction of the K-space lines...
متن کاملFast Concomitant Gradient Field Correction for Spiral Scans
Introduction: A major drawback to non-Cartesian imaging is the off-resonance blurring effects. Common linear techniques that remove the distortion effects are not sufficient, because the high order concomitant gradient fields are nontrivial for low fields and for scans that are more than 5 cm off isocenter [1]. Previous correction algorithms either are slow or do not take into account the known...
متن کاملGibbs-Ringing Artifact Removal Based on Local Subvoxel-shifts
PURPOSE To develop a fast and stable method for correcting the gibbs-ringing artifact. METHODS Gibbs-ringing is a well-known artifact which manifests itself as spurious oscillations in the vicinity of sharp image gradients at tissue boundaries. The origin can be seen in the truncation of k-space during MRI data-acquisition. Correction techniques like Gegenbauer reconstruction or extrapolation...
متن کاملNovel Motion Correction Technique Using Orbital Navigator Echoes in Interleaved Spiral Imaging
Spiral imaging does not produce apparent flow artifacts. However, it remains sensitive to rapid rigid body motion. In this abstract, a motion correction technique using an orbital navigator “ring” in interleaved spiral imaging is presented. In this technique, a circular k-space trajectory is incorporated into each spiral interleaf. Data inconsistency due to both rotation and translation can be ...
متن کاملEfficient Off-resonance Corrected Reconstruction of Rosette Trajectories by Deformed Interpolation Kernels
INTRODUCTION: With the use of multiple localized, small receive coil arrays, single shot whole brain coverage becomes feasible for fMRI applications. Using a 3D rosette trajectory and iterative, regularized reconstruction a 643 volume can be acquired in less than 30ms with acceptable broadening of the point spread function (1). Single shot trajectories suffer from off-resonance effects because ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 67 6 شماره
صفحات -
تاریخ انتشار 2012