Prospectively randomized evaluation of stented xenograft hemodynamic function in the aortic position.

نویسندگان

  • Thomas Walther
  • Sven Lehmann
  • Volkmar Falk
  • Sebastian Metz
  • Nicolas Doll
  • Ardawan Rastan
  • Marika Viehweg
  • Markus Richter
  • Jan Gummert
  • Friedrich W Mohr
چکیده

BACKGROUND Standard stented aortic xenograft valves have not yet been compared regarding their hemodynamic function using a stratified intraoperative randomization protocol. METHODS AND RESULTS 100 patients were prospectively included after intraoperative metric sizing of the decalcified aortic annulus. They received Mosaic (M) or Perimount (P) aortic valve replacement. Patient age was 73+/-5 years, 51 were female, and New York Heart Association (NYHA) functional class was 2.8+/-0.5. The 21-mm annulus group consisted of 5 (M)/7 (P) patients, the 23-mm annulus group of 20 (M)/20 (P), the 25-mm annulus group of 18 (M)/19 (P), and the 27-mm annulus group of 4 (M)/7 (P) patients, respectively. Hemodynamic function was evaluated using transthoracic echocardiography before discharge and at follow-up (438+/-352 days). Surgery was uncomplicated in all patients. Labeled valve sizes were 0.93 (M) and 1.05 (P) mm smaller than the annulus diameters (p=NS). In-hospital mortality was 5%, all nonvalve-related. Transvalvular blood flow velocities and transvalvular pressure gradients were significantly lower in the 25 P versus the 25 M group at baseline and in the 23 P and 25 P groups at follow-up. There was a significant regression of left ventricular mass index in all patients at follow-up. However, left ventricular mass regression was more pronounced after P aortic valve replacement. CONCLUSIONS Labeled sizes of prosthetic heart valves implanted are smaller than the true aortic annulus. Both standard aortic xenografts compared in this prospectively randomized trial provide a sufficient hemodynamic and functional outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Are stentless valves superior to modern stented valves? A prospective randomized trial.

BACKGROUND It is presumed that stentless aortic bioprostheses are hemodynamically superior to stented bioprostheses. A prospective randomized controlled trial was undertaken to compare stentless versus modern stented valves. METHODS AND RESULTS Patients with severe aortic valve stenosis (n=161) undergoing aortic valve replacement (AVR) were randomized intraoperatively to receive either the C-...

متن کامل

Performance of stentless versus stented aortic valve bioprostheses in the elderly patient: a prospective randomized trial.

OBJECTIVES Although stentless aortic bioprostheses are believed to offer improved outcomes, benefits remain unsubstantiated. The aim of our study was to compare stentless with stented bioprostheses, with regard to postoperative changes in left ventricular mass and hemodynamic performance, in the elderly patient. METHODS Forty patients with aortic stenoses, over the age of 75 years, were rando...

متن کامل

Full-root aortic valve replacement with stentless xenograft achieves superior regression of left ventricular hypertrophy compared to pericardial stented aortic valves

BACKGROUND Full-root aortic valve replacement with stentless xenografts has potentially superior hemodynamic performance compared to stented valves. However, a number of cardiac surgeons are reluctant to transform a classical stented aortic valve replacement into a technically more demanding full-root stentless aortic valve replacement. Here we describe our technique of full-root stentless aort...

متن کامل

Hemodynamic comparison of bioprostheses for complete supra-annular position in patients with small aortic annulus.

OBJECTIVES The present study evaluates complete supra-annular bioprostheses in patients with an aortic annulus of 18 to 23 mm in diameter. BACKGROUND Aortic valve replacement in patients with small aortic annulus using stented bioprostheses is often associated with unsatisfactory hemodynamic results and high incidence of patient-prosthesis mismatch. METHODS Between February 2000 and January...

متن کامل

Prospectively randomized evaluation of stented versus stentless aortic valve bioprostheses.

Doss et al. describe a series of 40 patients divided into two groups of 20 patients each. They do not give any information on whether statisticians had calculated this number of patients to allow for meaningful analysis. The implanted valve size of 23 mm is the only subgroup where minimal requirements of at least ten patients per valve size are scarcely reached. Results on intraoperatively meas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 110 11 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2004