Accuracy of thermistors and thermocouples as flow-measuring devices for detecting hypopnoeas.
نویسندگان
چکیده
The aim of this work was to assess the accuracy of thermistors/thermocouples as devices for detecting hypopnoeas in sleep studies. Conventional thermistor/thermocouples were studied with a respiratory model allowing the simulation of inspiratory (22 degrees C) and expiratory (37 degrees C) flows. The thermistor signal (V'th) was compared with a pneumotachograph (V'th): 1) for sinusoidal and square-wave airflows (+/-0.05 to +/-0.8 L.s(-1), 10-20 breaths.min(-1) (bpm)); 2) when changing the distance from the thermistor to the nose (0-20 mm); and 3) when doubling the section of the nostrils. The thermistor was strongly nonlinear and flow reductions (hypopnoeas) were underestimated: a 50% reduction in V' (+/-0.5 L.s(-1), 15 bpm, sinusoidal) resulted in only an 18% reduction in V'th. V'th depended considerably on the airflow pattern: for V'=+/-0.5 L.s(-1), V'th increased by 100% from sinusoidal (20 bpm) to square-wave (10 bpm). For V'=+/-0.5 L.s(-1), 15 bpm, sinusoidal flow, V'th increased by 79% when the distance thermistor-nose varied from 20-0 mm, and V'th decreased by 37% when doubling the nose section. We concluded that thermistor/thermocouples are inaccurate flow-measuring devices when used at the airflow conditions typical of sleep studies. Their use for quantifying hypopnoeas may lead to considerable underdetection of these respiratory events.
منابع مشابه
A method for detecting bubbles in two-phase gas-liquid flow
Detecting bubble in two-phase flow has been a basic issue in two-phase flow systems. A new method for measuring the frequency of bubble formation is presented in this paper. For this purpose, an electronic device was designed and constructed which works based on a change in intensity of laser beam. For this purpose, continues light beam is embedded just above the needle, which is received by a ...
متن کاملAccuracy and precision of "deep sternal" and tracheal temperatures at high- and low-fresh-gas flows.
The accuracy of tracheal temperature as a measure of core temperature is relatively poor during high-flow ventilation (6 litre min-1 fresh-gas flow). It is unknown if accuracy improves when lower fresh-gas flow rates are used. We tested the hypothesis that tracheal temperature accuracy would improve with low-flow ventilation (1 litre min-1). We studied 20 ASA Physical Status I and II patients u...
متن کاملRecent Evolutions of the Microcalorimeter Technique
The microcalorimeter technique continues to be the key technique for the realization of the primary power standards in the high frequency, because at the state of the art, only it allows tracing the power standards to the direct current standard, that is a SI quantity. This traceability is obtained through the determination of the effective efficiency, usually indicated by € ηe, of a power sens...
متن کاملررسی تجربی افت فشار جریان جوششی مبرد R-134a در لولههای افقی
The pressure drop of refrigerant R-134a flow boiling inside a horizontal tube has been investigated experimentally. The test set-up which was used in this investigation is a well instrumented vapor compression refrigeration system. These instruments are thermocouples, flow meter, pressure gauges and the pressure drop measuring apparatus. This system consisted of three electrically heated evapor...
متن کاملEstimate the Performance of Catalytic Converter Using Turbulence Induce Devices
In this manuscript, the experimental setup was designed and fabricated for optimizing the parameters of a catalytic converter of INDICA V2 exhaust system. Three turbulence intensify devices, namely Swirl Venturi, Swirl Blades and Swirl Contour, were close-fitted before the catalytic converter. The heating element is embedded in its body and thermocouples are used for knowing the performance at ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 11 1 شماره
صفحات -
تاریخ انتشار 1998