The health system impact of false positive newborn screening results for medium-chain acyl-CoA dehydrogenase deficiency: a cohort study

نویسندگان

  • Maria D. Karaceper
  • Pranesh Chakraborty
  • Doug Coyle
  • Kumanan Wilson
  • Jonathan B. Kronick
  • Steven Hawken
  • Christine Davies
  • Marni Brownell
  • Linda Dodds
  • Annette Feigenbaum
  • Deshayne B. Fell
  • Scott D. Grosse
  • Astrid Guttmann
  • Anne-Marie Laberge
  • Aizeddin Mhanni
  • Fiona A. Miller
  • John J. Mitchell
  • Meranda Nakhla
  • Chitra Prasad
  • Cheryl Rockman-Greenberg
  • Rebecca Sparkes
  • Brenda J. Wilson
  • Beth K. Potter
چکیده

BACKGROUND There is no consensus in the literature regarding the impact of false positive newborn screening results on early health care utilization patterns. We evaluated the impact of false positive newborn screening results for medium-chain acyl-CoA dehydrogenase deficiency (MCADD) in a cohort of Ontario infants. METHODS The cohort included all children who received newborn screening in Ontario between April 1, 2006 and March 31, 2010. Newborn screening and diagnostic confirmation results were linked to province-wide health care administrative datasets covering physician visits, emergency department visits, and inpatient hospitalizations, to determine health service utilization from April 1, 2006 through March 31, 2012. Incidence rate ratios (IRRs) were used to compare those with false positive results for MCADD to those with negative newborn screening results, stratified by age at service use. RESULTS We identified 43 infants with a false positive newborn screening result for MCADD during the study period. These infants experienced significantly higher rates of physician visits (IRR: 1.42) and hospitalizations (IRR: 2.32) in the first year of life relative to a screen negative cohort in adjusted analyses. Differences in health services use were not observed after the first year of life. CONCLUSIONS The higher use of some health services among false positive infants during the first year of life may be explained by a psychosocial impact of false positive results on parental perceptions of infant health, and/or by differences in underlying health status. Understanding the impact of false positive newborn screening results can help to inform newborn screening programs in designing support and education for families. This is particularly important as additional disorders are added to expanded screening panels, yielding important clinical benefits for affected children but also a higher frequency of false positive findings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Newborn screening for medium chain acyl-CoA dehydrogenase deficiency: performance improvement by monitoring a new ratio.

Medium chain acyl-CoA dehydrogenase (MCAD) deficiency is a fatty acid oxidation disorder included on newborn screening (NBS) panels in many regions that have expanded to using tandem mass spectrometry for acylcarnitine screening. False positive (FP) screening results for MCAD deficiency have previously been linked to very low birth weight (VLBW) infants and those who are heterozygous for the co...

متن کامل

Rapid diagnosis of MCAD deficiency: quantitative analysis of octanoylcarnitine and other acylcarnitines in newborn blood spots by tandem mass spectrometry.

We report the application of tandem mass spectrometry to prospective newborn screening for medium-chain acyl-CoA dehydrogenase (MCAD) deficiency. MCAD deficiency is diagnosed from dried blood spots on filter paper cards from newborns on the basis of the increase of medium chain length acylcarnitines identified by isotope dilution mass spectrometry methods. A robust and accurate semiautomated me...

متن کامل

Cost-effectiveness analysis of universal newborn screening for medium chain acyl-CoA dehydrogenase deficiency in France

BACKGROUND Five diseases are currently screened on dried blood spots in France through the national newborn screening programme. Tandem mass spectrometry (MS/MS) is a technology that is increasingly used to screen newborns for an increasing number of hereditary metabolic diseases. Medium chain acyl-CoA dehydrogenase deficiency (MCADD) is among these diseases. We sought to evaluate the cost-effe...

متن کامل

Medium chain acyl-CoA dehydrogenase deficiency in a premature infant

Medium-chain acyl-CoA dehydrogenase deficiency (MCADD) is identified by newborn screening (NBS). The natural history of MCADD includes metabolic decompensation with hypoglycemia, hyperammonemia, seizures, coma, and death. NBS enables expectant management thus severe symptoms are rare in managed patients. We report premature birth of an MCADD affected infant and resultant management challenges. ...

متن کامل

Economics of tandem mass spectrometry screening of neonatal inherited disorders.

OBJECTIVES The aim of this study was to evaluate the cost-effectiveness of neonatal screening for phenylketonuria (PKU) and medium-chain acyl-coA dehydrogenase (MCAD) deficiency using tandem mass spectrometry (tandem MS). METHODS A systematic review of clinical efficacy evidence and cost-effectiveness modeling of screening in newborn infants within a UK National Health Service perspective was...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016