Results from a degradable TMC joint Spacer (Artelon) compared with tendon arthroplasty.

نویسندگان

  • Anders Nilsson
  • Elisabeth Liljensten
  • Christina Bergström
  • Christer Sollerman
چکیده

PURPOSE A new spacer for the trapeziometacarpal joint (TMC) based on a biological and tissue-preserving concept for the treatment of TMC osteoarthritis (OA) has been evaluated. The purpose was to combine a spacing effect with stabilization of the TMC joint. METHODS Artelon (Artimplant AB, Sweden) TMC Spacer is synthesized of a degradable polyurethaneurea (Artelon), which has been shown to be biocompatible over time and currently is used in ligament augmentation procedures. Fibers of the polymer were woven into a T-shaped device in which the vertical portion separates the bone edges of the TMC joint and the horizontal portion stabilizes the joint. Fifteen patients with disabling pain and isolated TMC OA were included in the study. Ten patients received the spacer device and the remaining 5 (control group) were treated with a trapezium resection arthroplasty with abductor pollicis longus (APL) stabilization. The median ages of the 2 groups were 60 and 59 years, respectively. Pain, strength, stability, and range of motion were measured before and after surgery. Radiographic examination was performed in all patients before and after surgery. At follow-up evaluation 3 years after surgery an unbiased observer evaluated all patients. Biopsy specimens were obtained from 1 patient 6 months after surgery. RESULTS All patients were stable clinically without signs of synovitis. In both groups all patients were pain free. The median values for both key pinch and tripod pinch increased compared with before surgery in the spacer group but not in the APL group. The biopsy examinations showed incorporation of the device in the surface of the adjacent bone and the surrounding connective tissue. No signs of foreign-body reaction were seen. CONCLUSIONS This study showed significantly better pinch strength after Artelon TMC Spacer implantation into the TMC joint compared with APL arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Artelon CMC spacer compared with tendon interposition arthroplasty

BACKGROUND AND PURPOSE The Artelon CMC spacer is designed for surgical treatment of osteoarthritis (OA) in the carpometacarpal joint of the thumb (CMC-I). Good results using this degradable device were previously presented in a pilot study. We now present results from a larger randomized, controlled, multicenter study. PATIENTS AND METHODS 109 patients (94 females) with a mean age of 60 (42-8...

متن کامل

Treatment of thumb carpometacarpal arthritis with arthroscopic hemitrapeziectomy and interposition arthroplasty.

The carpometacarpal joint of the thumb is a common site of degenerative arthritis. Several surgical treatments exist, but arthroscopic management offers the potential benefit of earlier recovery. The current study evaluated the early clinical outcomes of a procedure involving arthroscopic hemitrapeziectomy with Artelon spacer (Artimplant, Västra Frölunda, Sweden) interposition arthroplasty into...

متن کامل

Trapezium prosthetic arthroplasty (silicone, Artelon, metal, and pyrocarbon).

Trapezium prosthetic arthroplasty has been utilized to treat basal joint arthritis for nearly five decades in an attempt to mitigate some of the potential disadvantages of trapeziectomy while preserving range of motion. Implant arthroplasty seeks to preserve joint biomechanics, avoids metacarpal subsidence, and should provide immediate stability. These benefits may lead to improvements in stren...

متن کامل

Use of Artelon® Cosmetic in soft tissue augmentation in dentistry

BACKGROUND Soft tissue augmentation is a widely used procedure in partially and fully edentulous patients to increase soft tissue volume. Polyurethanes have been used for scaffolds in a variety of implantable devices. Artelon(®) is a degradable polyurethane that has been manufactured as fibers, films, and porous scaffolds to be used for various purposes. In this review, the characteristics of A...

متن کامل

Preserving the Posttrapeziectomy Space with a Human Acellular Dermal Matrix Spacer: A Pilot Case Series of Patients with Thumb Carpometacarpal Joint Arthritis

BACKGROUND Advanced thumb carpometacarpal arthritis is widely treated with trapeziectomy and tendon interposition despite donor-site morbidities. Trapeziectomy alone leaves a postresection space, leading to proximal metacarpal migration and scaphoid/trapezoid impingement. Prosthetic implants have been unsuccessful due to particulate debris, silicone synovitis, osteolysis, and migration. Recent ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of hand surgery

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 2005