CLINICAL CARDIOLOGY: PHYSICIAN UPDATE Use of Intracardiac Echocardiography to Guide Ablation of Atrial Fibrillation

نویسندگان

  • Joshua M. Cooper
  • Laurence M. Epstein
چکیده

Intracardiac Echocardiography Ultrasound technology has progressed rapidly over the past several years, leading to significant miniaturization of transducer design. The original catheter-based transducers, known as intravascular ultrasound (IVUS) catheters, are high frequency (20 to 40 MHz) and are used to image the walls of coronary arteries and other small vessels. They contain a single ultrasound crystal that rapidly rotates in the end of the catheter, offering a circumferential, 2-dimensional image. Although this high-frequency transducer provides excellent near-field spatial resolution, its acoustic depth is limited to several millimeters, thus making it suitable for intracoronary imaging. Transducers with lower frequencies (5 to 12 MHz) have been developed to apply catheter-based echocardiography to intracardiac imaging, which requires greater ultrasound penetration than intravascular imaging. Two types of ultrasound catheters are currently in use. The first is a mechanical echo catheter, which is similar to IVUS catheters, with a rotating ultrasound transducer driven by a motor unit at the opposite end of a braided drive shaft, which results in a 360-degree view perpendicular to the catheter. The second type is a fixed or phased array echo catheter that uses electronically controlled multiple transducers affixed to one side of the catheter shaft, which results in a wedge-shaped image sector similar to that of a transesophageal echo probe. Both types of catheters provide high resolution, real-time images of anatomic structures and of other intracardiac devices and catheters. Echo catheters are currently 6 to 10 French, and are typically introduced through a sheath in a femoral vein. Phased array catheters offer a large depth of field and the possibility of Doppler imaging, whereas mechanical catheters offer better near-field resolution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intracardiac Echocardiography during Catheter-Based Ablation of Atrial Fibrillation

Accurate delineation of the variable left atrial anatomy is of utmost importance during anatomically based ablation procedures for atrial fibrillation targeting the pulmonary veins and possibly other structures of the atria. Intracardiac echocardiography allows real-time visualisation of the left atrium and adjacent structures and thus facilitates precise guidance of catheter-based ablation of ...

متن کامل

Intracardiac echocardiography-guided, anatomically based radiofrequency ablation of focal atrial fibrillation originating from pulmonary veins.

OBJECTIVES In patients with a pulmonary vein (PV) source for atrial fibrillation (AF), we sought the use of intracardiac echocardiography (ICE) to evaluate PV anatomy, guide radiofrequency (RF) ablation and monitor for acute stenosis during ablation. BACKGROUND A focal source for AF may be found in the proximal component of the PVs and can be effectively treated by ablative techniques. Howeve...

متن کامل

Left atrial thrombus associated with ablation for atrial fibrillation: identification with intracardiac echocardiography.

OBJECTIVES This study reports the incidence of, risk factors for, and management of left atrial (LA) thrombus documented by intracardiac echocardiography (ICE) during LA ablation for atrial fibrillation (AF). BACKGROUND Thrombus formation is a risk associated with LA ablation procedures. METHODS Intracardiac echocardiography imaging was performed in 232 patients (184 men, average age 55 +/-...

متن کامل

Intracardiac Echocardiography in Catheter Ablation for Atrial Fibrillation: It Is Better to See What You Are Doing?

Current advanced technology allows the accurate three-dimensional reconstruction of cardiac structures using multiple images from two-dimensional intracardiac echocardiography (ICE). This technology is applicable to atrial fibrillation (AF) ablation and provides real-time anatomical information on relevant atrial structures and myocardial thickness as well as suitable sites for transseptal punc...

متن کامل

Catheter ablation of atrial fibrillation without fluoroscopy using intracardiac echocardiography and electroanatomic mapping.

BACKGROUND Catheter ablation of atrial fibrillation is currently guided by x-ray fluoroscopy. The associated radiation risk to patients and medical staff may be significant. We report an atrial fibrillation ablation technique using intracardiac echocardiography (ICE) and electroanatomic mapping without fluoroscopy. METHODS AND RESULTS Twenty-one patients with atrial fibrillation (age, 42 to 7...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001