The correlation between the first heart sound and cardiac output as measured by using digital esophageal stethoscope under anaesthesia

نویسندگان

  • Young Duck Shin
  • Kyoung Hoon Yim
  • Sang Hi Park
  • Yong Wook Jeon
  • Jin Ho Bae
  • Tae Soo Lee
  • Myoung Hwan Kim
  • Young Jin Choi
چکیده

OBJECTIVE The use of an esophageal stethoscope is a basic heart sounds monitoring procedure performed in patients under general anesthesia. As the size of the first heart sound can express the left ventricle function, its correlation with cardiac output should be investigated. The aim of this study was to investigate the effects of cardiac output (CO) on the first heart sound (S1) amplitude. Methods : Six male beagles were chosen. The S1 was obtained with the newly developed esophageal stethoscope system. CO was measured using NICOM, a non-invasive CO measuring device. Ephedrine and beta blockers were administered to the subjects to compare changes in figures, and the change from using an inhalation anesthetic was also compared. RESULTS The S1 amplitude displayed positive correlation with the change rate of CO (r = 0.935, p < 0.001). The heart rate measured using the esophageal stethoscope and ECG showed considerably close figures through the Bland-Altman plot and showed a high positive correlation (r = 0.988, p < 0,001). CONCLUSION In beagles, the amplitude of S1 had a significant correlation with changes in CO in a variety of situations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is u...

متن کامل

Correlation of blood pressure and the ratio of S1 to S2 as measured by esophageal stethoscope and wireless bluetooth transmission

UNLABELLED Objective : Esophageal stethoscope has the advantage of being non-invasive, easily placed and capability to monitor the heart sound. This study was designed to determine whether the ratio of S1 to S2 analyzed by esophageal stethoscope and wireless bluetooth transmission can be accurate indicator that express the correlation with blood pressure. METHODS Total 33 adult male and femal...

متن کامل

A New Stethoscope Design with Unique Characteristics and Development in Medical Device

As regards the significant role of stethoscopes in the diagnosis of congenital and adventitious heart diseases and prevention of irreparable complications of these diseases, the quality of hearing sound of these stethoscopes by a physician has a significant impact on the disease diagnosis. This device plays an important role in the early diagnosis of congenital heart and respiratory diseases an...

متن کامل

A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

BACKGROUND The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is un...

متن کامل

Automatic classification of normal and abnormal cardiac sounds by combining features based on wavelet transform and capstral coefficients extracted from PCG signals (Research Article)

Cardiac sounds are produced by the mechanical activities of the heart and provide useful information about the function of the heart valves. Due to the transient and unstable nature of the heart's sound and the limitation of the human hearing system, it is difficult to categorize heart sound signals based on what is heard from a stethoscope. Therefore, providing an automated algorithm for prima...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 30  شماره 

صفحات  -

تاریخ انتشار 2014