Transvenous versus open chest lead placement for resynchronization therapy in patients with heart failure: comparison of ventricular electromechanical synchronicity

نویسندگان

  • Hai-Bo Zhang
  • Xu Meng
  • Jie Han
  • Yan Li
  • Ye Zhang
  • Teng-Yong Jiang
  • Ying-Xin Zhao
  • Yu-Jie Zhou
چکیده

BACKGROUND Transvenous lead placement is the standard approach for left ventricular (LV) pacing in cardiac resynchronization therapy (CRT), while the open chest access epicardial lead placement is currently the most frequently used second choice. Our study aimed to compare the ventricular electromechanical synchronicity in patients with heart failure after CRT with these two different LV pacing techniques. METHODS We enrolled 33 consecutive patients with refractory heart failure secondly to dilated cardiomyopathy who were eligible for CRT in this study. Nineteen patients received transvenous (TV group) while 14 received open chest (OP group) LV lead pacing. Intra- and inter-ventricular electromechanical synchronicity was assessed by tissue Doppler imaging (TDI) before and one year after CRT procedure. RESULTS Before CRT procedure, the mean QRS-duration, maximum time difference to systolic peak velocity among 12 left ventricle segments (LV Ts-12), standard deviation of time difference to systolic peak velocity of 12 left ventricle segments (LV Ts-SD), and inter-ventricular mechanical delay (IVMD) in OP and TV group were 166 ± 17 ms and 170 ± 21 ms, 391 ± 42 ms and 397 ± 36 ms, 144 ± 30 ms and 148 ± 22 ms, 58 ± 25 ms and 60 ± 36 ms, respectively (all P > 0.05). At one year after the CRT, the mean QRS-duration, LV Ts-12, LV Ts-SD, and IVMD in TV and OP group were 128 ± 14 ms and 141 ± 22 ms (P = 0.031), 136 ± 37 ms and 294 ± 119 ms (P = 0.023), 50 ± 22 ms and 96 ± 34 ms (P = 0.015), 27 ± 11 ms and 27 ± 26 ms (P = 0.86), respectively. The LV lead implantation procedure time was 53.4 ± 16.3 min for OP group and 136 ± 35.1 min for TV group (P = 0.016). The mean LV pacing threshold increased significantly from 1.7 ± 0.6 V/0.5 ms to 2.3 ± 1.6 V/0.5 ms (P < 0.05) in TV group while it remained stable in the OP group. CONCLUSIONS Compared to conventional endovascular approach, open chest access of LV pacing for CRT leads to better improvement of the intraventricular synchronization.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Echocardiography-guided left ventricular lead placement for cardiac resynchronization therapy: results of the Speckle Tracking Assisted Resynchronization Therapy for Electrode Region trial.

BACKGROUND Cardiac resynchronization therapy improves mortality and morbidity in patients with heart failure (HF) with wide QRS complex and diminished left ventricular (LV) function, but response is variable. METHODS AND RESULTS The Speckle Tracking Assisted Resynchronization Therapy for Electrode Region (STARTER) was a prospective, double-blind, randomized controlled trial testing the hypoth...

متن کامل

Cardiac Resynchronization Therapy

In this issue of the Journal, Giraldi et al. (1) compare transvenous and epicardial lead placement in patients with unfavorable coronary sinus anatomy. Patients who met standard criteria for cardiac resynchronization therapy (CRT) including left ventricular (LV) dysfunction, New York Heart Association class III to IV congestive heart failure, and left bundle branch block, who were on optimal me...

متن کامل

Maximal electric separation-guided placement of right ventricular lead improves responders in cardiac resynchronization defibrillator therapy.

BACKGROUND Cardiac resynchronization therapy is widely used for the treatment of heart failure. Recent data suggest that electric separation during left ventricular pacing varies within the right ventricle (RV). We hypothesized that placement of the RV lead guided by maximal electric separation (MES) would improve response to cardiac resynchronization therapy compared with standard apical place...

متن کامل

Implantation Techniques of Leads for Left Ventricular Pacing in Cardiac Resynchronization Therapy and Electrocardiographic Consequences of the Stimulation Site

The first descriptions of beneficial effects of left ventricular (LV) or simultaneous LV and right ventricular (RV) pacing were published more than 35 years ago (Vagnini et al.,1967; Tyers et al.,1970; Gibson et al.,1971). In 1994 Cazeau published the first successful cases of biventricular pacing in patients with severe congestive heart failure (CHF) and no conventional indication for cardiac ...

متن کامل

Thoracoscopic Left Ventricular Lead Implantation in Cardiac Resynchronization Therapy

Cardiac resynchronization therapy is known to reduce morbidity and mortality in patients with advanced heart failure as a result of dyssynchrony and systolic dysfunction of the left ventricle. Placement of the left ventricular (LV) lead via the coronary sinus can be difficult. When LV lead implantation is difficult, a video-assisted epicardial approach can be a good alternative. Although there ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2017