Field additivity of the middle-wavelength cone pathway under various test and field configurations
نویسندگان
چکیده
The field additivity of the M-cone pathway was measured with psychometric functions at 10 times absolute threshold on monochromatic fields and their mixtures. Observers detected a 500 nm test on 530 or 610 nm fields, and a 530 nm test on 481 or 622 nm fields. For both sets of wavelengths, field additivity held with the 1 deg test, 10 deg field condition which defines II-4 and with the 3.6 min are test on a 8.6 min arc field used to isolate the M fundamental by Stockman [(1983) Ph. D. thesis, Trinity College, Cambridge University, Cambridge]. Sub-additivity occurred for a 1 deg test on a 1 deg field, a condition for Foster's "spectral sharpening" which may evince opponency.
منابع مشابه
Brightness induction from rods.
Rod modulation of an annular surround can produce brightness contrast in a test field centered at 100 from the fovea. In our research, stimuli originated from a colorimeter that provided 4 primaries in both the circular test and the annular surround fields, and allowed independent modulation of the rods and each of the short (S)-, middle (M)-, and long (L)-wavelength-sensitive cone types. The c...
متن کاملFavorable Plug Shape of an Aerospike Nozzle in Design, Over and Under Expansion Conditions
The influence of the plug shape on the performance of an aerospike nozzle thrust force is studied in different back pressure conditions. To generate smooth plug contours, Cubic B-Spline technique is employed. In the current research, basis functions are obtained using Deboor’s relation. The flow field around the aerospike nozzle is investigated implementing various shapes and the best of the ge...
متن کاملFour cone pigments in women heterozygous for color deficiency.
It is generally accepted that human color matching is trichromatic (requires three primaries) because there are three types of cone, each containing one visual pigment. A color match between two stimulus fields is thought to be determined at the receptor level where the rate of quantum absorption by each of the three cone pigments must be equated to obtain a color match. Since there are three c...
متن کاملColor appearance under chromatic adaptation varied along theoretically significant axes in color space.
Changes in color appearance caused by chromatic adaptation were measured with a wide range of adapting fields. Observers viewed a 39'-55' annular test field composed of an admixture of lights from the red phosphor and the green phosphor of a CRT. The annular mixture field was centered and superimposed upon a 4.7 degrees steady, circular background field. After the observer was completely adapte...
متن کاملThe spectral sensitivities of the middle- and long-wavelength cones: an extension of the two-colour threshold technique of W S Stiles.
When a tiny centred test flash is presented on a small concentric background, the threshold rises with background radiance more quickly than Weber's law would predict. It is argued that under such conditions it is possible, by means of a test sensitivity method, to isolate either the M-cone or the L-cone types throughout the visible spectrum. As predicted, double-branched M- and L-cone tyr func...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vision Research
دوره 35 شماره
صفحات -
تاریخ انتشار 1995