A rare complication of carotid artery stenting: displacement of marker ring causing locking of stent and incomplete stent expansion.

نویسندگان

  • E Akgul
  • E H Aksungur
  • K Korur
  • K Aikimbaev
  • H Yaliniz
چکیده

We present a rare case of a complication of placement of a carotid artery stent represented by partial opening of a carotid Wallstent caused by displacement of its metal ring marker, which thus hindered complete expansion of the stent. An intraluminally locked carotid stent necessitated referral of the patient for urgent carotid endarterectomy. A possible reason of this unusual complication can be a manufacturing defect, which, to our knowledge, was not documented previously in open public data bases or on the Internet.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Delayed Cerebral Infarction due to Stent Folding Deformation Following Carotid Artery Stenting

We report a case of delayed cerebral infarction due to stent longitudinal folding deformation following carotid artery stenting using a self-expandable stent with an open-cell design. The stented segment of the left common carotid artery was divided into two different lumens by this folding deformation, and the separated lumens became restricted with in-stent thrombosis. Although no established...

متن کامل

Rescue Use of Tirofiban for Acute Carotid In-Stent Thrombosis

Carotid artery stenting is widely performed for extracranial carotid artery stenosis. In-stent thrombosis is a rare but potentially devastating complication. We present a case of acute in-stent thrombosis immediately following stent insertion and post-balloon dilatation in a 64-year-old male. Thrombosis was successfully treated by intravenous tirofiban, a glycoprotein IIb/IIIa receptor inhibitor.

متن کامل

Optimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique

Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...

متن کامل

Acute carotid stent thrombosis after carotid artery stenting.

BACKGROUND Carotid artery stenting (CAS) is a reasonable alternative to carotid endarterectomy (CEA), especially in patients at high risk for surgery. Carotid artery thrombosis of the treated segment is a rare, early but potentially devastating complication of this endovascular procedure. The aim of this article is to identify and critically review cases of acute stent thrombosis reported in th...

متن کامل

Closed External End Double J Catheter as a Nephrostent in Pyeloplasty for Infants with Uretero-Pelvic Junction Obstruction

Uretero-Pelvic Junction Obstruction (UPJO) is a common congenital anomaly that may need pyeloplasty to prevent renal function deterioration. The purpose of this study was to describe a modified use of jj stent catheter in pyeloplasty for infant with UPJO. A series of 12 children, between 3 and 10 months, underwent stenting open pyeloplasty. In each patient a 6 French Foley catheter was placed w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 28 7  شماره 

صفحات  -