A 3D quantitative evaluation for assessing the changes of treatment planning system and irradiation techniques in radiotherapy

نویسندگان

  • Abdulhamid Chaikh
  • Jean Yves Giraud
  • Jacques Balosso
چکیده

Purpose: This work proposes and compares two 3D global evaluation methods for assessing the alteration of calculated dose distributions when treatment planning system algorithms or irradiation techniques is modified in radiation therapy. Methods: The global analysis is based on gamma index (γ) proposed by Low et al.1 and Chi (χ) index proposed by Bakai et al.2. The γ and χ values are signed in order to identify the over and under estimating dosage. The 3D maps, the cumulative Gamma Voxels Histograms (GVHs) and Chi Voxels Histograms (CVHs) were generated using two software. The γ and χ criteria were set to 3 mm for the distance to agreement and 3% for dose. Pearson's Chi-squared test was applied to assess the statistically significance between GVHs and CVHs. We illustrated this method for the change of dose calculation algorithms for lung cancer, and the change of irradiation techniques for breast cancer. For each patient, 2 treatment plans were generated. For the example of change of dose calculation algorithms, a plan 1 was calculated using Pencil Beam Convolution (PBC) algorithm and a plan 2 was calculated using Modified Batho method (PBC-MB). For the example of change of irradiation technique, a plan 1 was calculated using Source Skin Distance SSD technique and a plan 2 was calculated using a single isocenter technique. Results: The 3D analysis based on γ and χ indexes showed a significant effect on the dosimetric representation in the lung cancer when we change the PBC algorithm to PBC-MB method. The comparison between the two irradiation techniques showed that the single isocenter technique produces a better dose distribution for the treatment of breast cancer. Pearson's Chi-squared test showed that there was no statistically significance between GVHs and CVHs generated by γ and χ indexes, (p > 0.05). The global analysis using 3D for γ and χ indexes confirmed the results obtained from dosimetric analysis. Conclusion: The methods proposed in this study provide useful tools for radiotherapy to compare two dose distributions obtained using different algorithms or different irradiation techniques. The χ-index was (~190) times faster than γ-index. The χ-index is thus a valuable and more convenient method for 3D global analysis compared with γ-index.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Dose Calculation Accuracy of Isogray Treatment Planning System in Craniospinal Radiotherapy

Introduction: Craniospinal radiotherapy is a therapeutic technique for central nervous system (CNS) tumors, which requires meticulous attention to technique and dosimetry.Treatment planning system (TPS) is one of the main equipment in radiotherapy; therefore, the evaluation of its accuracy is essential for dose calculation. The present study evaluates the validity of Isogray TPS in craniospinal...

متن کامل

Dosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies

Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...

متن کامل

Evaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques

Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field ...

متن کامل

Evaluation of changes in excision cavity volume during whole breast irradiation using secondary CT image

Background: The aim of this study was to evaluate the reduction in excision cavity volume (ECV) during the whole breast radiotherapy (WBRT). The delineating of reduced cavity volume on secondary CT (computed tomography) might decrease the field size of boost plan. Materials and Methods: Twenty patients were treated having breast conservative surgery. At first, primary CT simulation (CT-1) was d...

متن کامل

The Comparison 2D and 3D Treatment Planning in Breast Cancer Radiotherapy with Emphasis on Dose Homogeneity and Lung Dose

Introduction: Breast conserving radiotherapy is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is usually used for this purpose. This technique is performed using 2D or 3D treatment planning systems. The aim of this study was to compare 2D treatment planning with 3D treatment planning in tangential irradiation in breast conse...

متن کامل

Dosimetric comparison of conventional and field-in-field techniques in early stage breast cancer radiotherapy

Introduction: Breast conserving surgery followed by adjuvant radiotherapy (RT) of the whole breast is accepted as the treatment of choice in early stage breast cancer. Due to breast irregularities, it is difficult to access homogenous dose distribution with conventional techniques. Currently, it is possible to use varied breast irradiation techniques, such as field- in-field (F...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -