Retinal burns caused by exposure to MIG-welding arcs: report of two cases.

نویسنده

  • G P Brittain
چکیده

A new generation of arc welder has recently become widely available at a price which is within reach of most amateurs and part-time mechanics, known as the MIG welder (metal-arc inert gas welder). In MIG welding the arc is ensheathed in a stream of inert gas which prevents the molten metal from oxidising. The stream of gas changes the character of the emitted radiation, and it is possible that this type of welder poses a greater threat to sight than previously recognised. Radiation in the ultraviolet range emitted by arc welders is absorbed by the unprotected cornea and lens, giving rise to a keratoconjunctivitis, or 'arc-eye,' which, though intensely painful, is not considered a threat to sight. Radiation in the visible and near infrared spectrum, however, penetrates the eye to be absorbed by the retina and may cause thermal or photochemical damage which may be permanent and sight-threatening. Retinal injuries resulting from exposure to ordinary electric welding arcs have been reported, but such injuries are uncommon. Two cases of retinal burns resulting from exposure to MIG welder emissions which presented on consecutive days to the Leicester Royal Infirmary are presented. This is the first report of such injuries relating specifically to MIG welding.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retinal burns from MIG-welding arcs.

SIR, I read the article by G P H Brittain' on retinal burns caused by exposure to MIG-welding arcs with great interest. I had not seen any cases in Australia and so I was very interested to study the illustrations. Two cases were described. The first case was illustrated in Fig. 2 but I could not see the 'small dark lesion above each fovea' said to be present. The second case is illustrated in ...

متن کامل

Bilateral Macular Hemorrhage Due to Welding Arc: A Case Report

Background and Objective: Non-ionized radiation from arc welding may cause retinal lesions such as photo retinitis. In this report, a patient with bilateral macular bleeding which had been caused by inappropriate use of protective safety glasses is introduced. Case Report: On 26 July 2008 a 23-year-old male with blurred vision was referred to Shahid Beheshti's faculty of Rehabilitation Clinic....

متن کامل

Optimization of TIG-MIG hybrid welding of 316L austenitic stainless steel

In the TIG-MIG hybrid welding, higher weld efficiency and better weld quality are obtained with respect to each individual TIG and MIG welding methods. Moreover, in this method, the MIG arc is more stable in pure argon shielding gas. Therefore, in this study, the influence of TIG-MIG hybrid welding parameters on the welds appearance quality and welds depth to width ratio of a 316L austenitic st...

متن کامل

Optimization of TIG-MIG hybrid welding of 316L austenitic stainless steel

In the TIG-MIG hybrid welding, higher weld efficiency and better weld quality are obtained with respect to each individual TIG and MIG welding methods. Moreover, in this method, the MIG arc is more stable in pure argon shielding gas. Therefore, in this study, the influence of TIG-MIG hybrid welding parameters on the welds appearance quality and welds depth to width ratio of a 316L austenitic st...

متن کامل

Exposure of welders and other metal workers to ELF magnetic fields.

This study assessed exposure to extremely low frequency (ELF) magnetic fields of welders and other metal workers and compared exposure from different welding processes. Exposure to ELF magnetic fields was measured for 50 workers selected from a nationwide cohort of metal workers and 15 nonrandomly selected full-time welders in a shipyard. The measurements were carried out with personal exposure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 72 8  شماره 

صفحات  -