An accessible micro-capillary electrophoresis device using surface-tension-driven flow.
نویسندگان
چکیده
We present a rapidly fabricated micro-capillary electrophoresis chip that utilizes surface-tension-driven flow for sample injection and extraction of DNA. Surface-tension-driven flow (i.e. passive pumping) [G. M. Walker et al., Lab. Chip. 2002, 2, 131-134] injects a fixed volume of sample that can be predicted mathematically. Passive pumping eliminates the need for tubing, valves, syringe pumps, and other equipment typically needed for interfacing with microelectrophoresis chips. This method requires a standard micropipette to load samples before separation, and remove the resulting bands after analysis. The device was made using liquid phase photopolymerization to rapidly fabricate the chip without the need of special equipment typically associated with the construction of microelectrophoresis chips (e.g. cleanroom) [A. K. Agarwal et al., J. Micromech. Microeng. 2006, 16, 332-340; S. K. Mohanty et al., Electrophoresis 2006, 27, 3772-3778]. Batch fabrication time for the device presented here was 1.5 h including channel coating time to suppress electroosmotic flow. Devices were constructed out of poly-isobornyl acrylate and glass. A standard microscope with a UV source was used for sample detection. Separations were demonstrated using Promega BenchTop 100 bp ladder in hydroxyl ethyl cellulose (HEC) and oligonucleotides of 91 and 118 bp were used to characterize sample injection and extraction of DNA bands. The end result was an inexpensive micro-capillary electrophoresis device that uses tools (e.g. micropipette, electrophoretic power supplies, and microscopes) already present in most labs for sample manipulation and detection, making it more accessible for potential end users.
منابع مشابه
Control of initiation, rate, and routing of spontaneous capillary-driven flow of liquid droplets through microfluidic channels on SlipChip.
This Article describes the use of capillary pressure to initiate and control the rate of spontaneous liquid-liquid flow through microfluidic channels. In contrast to flow driven by external pressure, flow driven by capillary pressure is dominated by interfacial phenomena and is exquisitely sensitive to the chemical composition and geometry of the fluids and channels. A stepwise change in capill...
متن کاملFixing colloidal motions at water/air interface with micrometer scale resolution.
Fast colloidal motions driven by surface tension gradient are created in a thin water layer. Unlike using solid boundaries to limit the colloidal flow, our work relaxes this condition by directly placing bulk fluid next to an open air environment. When the colloidal flow along the air/water interface is interfered with stationary objects, repetitive semicircular motions, that is, micro eddy, ar...
متن کاملFormation of complex polymeric microstructures through physical self-organization and capillary dynamics
We present a generic way of forming various complex polymeric microstructures using physical self-organization and capillary dynamics. A simple lithographic tool called capillary force lithography is utilized for this purpose, in which the pattern formation is driven by capillary force, not involving any external force or modification. In this method, a patterned polydimethylsiloxane mold is pl...
متن کاملEvaluation of Recirculation Time in Bubble Train Flow by Using Direct Numerical Simulation
In this research, hydrodynamics of the Bubble Train Flows (BTF) in circular capillaries has been investigated by Direct Numerical Simulation (DNS).The Volume of Fluid Based (VOF) interface tracking method and streamwise direction periodic boundary conditions has been applied. The results show that there exists an appropriate agreement between DNS and experimental correlation results. The re...
متن کاملSurface tension-driven self-alignment.
Surface tension-driven self-alignment is a passive and highly-accurate positioning mechanism that can significantly simplify and enhance the construction of advanced microsystems. After years of research, demonstrations and developments, the surface engineering and manufacturing technology enabling capillary self-alignment has achieved a degree of maturity conducive to a successful transfer to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Electrophoresis
دوره 30 9 شماره
صفحات -
تاریخ انتشار 2009