Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography.

نویسندگان

  • C K Hofer
  • L Furrer
  • S Matter-Ensner
  • M Maloigne
  • R Klaghofer
  • M Genoni
  • A Zollinger
چکیده

BACKGROUND End-diastolic volume indices determined by transpulmonary thermodilution and pulmonary artery thermodilution may give a better estimate of left ventricular preload than pulmonary capillary wedge pressure monitoring. The aim of this study was to compare volume preload monitoring using the two different thermodilution techniques with left ventricular preload assessment by transoesophageal echocardiography (TOE). METHODS Twenty patients undergoing elective cardiac surgery with preserved left-right ventricular function were studied after induction of anaesthesia. Conventional haemodynamic variables, global end-diastolic volume index using the pulse contour cardiac output (PiCCO) system (GEDVI(PiCCO)), continuous end-diastolic volume index (CEDVI(PAC)) measured by a modified pulmonary artery catheter (PAC), left ventricular end-diastolic area index (LVEDAI) using TOE and stroke volume indices (SVI) were recorded before and 20 and 40 min after fluid replacement therapy. Analysis of variance (Bonferroni-Dunn), Bland-Altman analysis and linear regression were performed. RESULTS GEDVI(PiCCO), CEDVI(PAC), LVEDAI and SVI(PiCCO/PAC) increased significantly after fluid load (P<0.05). An increase >10% for GEDVI(PiCCO) and LVEDAI was observed in 85% and 90% of the patients compared with 45% for CEDVI(PAC). Mean bias (2 SD) between percentage changes (delta) in GEDVI(PiCCO) and deltaLVEDAI was -3.2 (17.6)% and between deltaCEDVI(PAC) and deltaLVEDAI -8.7 (30.0)%. The correlation coefficient (r2) for deltaGEDVI(PiCCO) vs deltaLVEDAI was 0.658 and for deltaCEDVI(PAC) vs deltaLVEDAI 0.161. The relationship between deltaGEDVI(PiCCO) and deltaSVI(PiCCO) was stronger (r2=0.576) than that between deltaCEDVI(PAC) and deltaSVI(PAC) (r2=0.267). CONCLUSION GEDVI assessed by the PiCCO system gives a better reflection of echocardiographic changes in left ventricular preload, in response to fluid replacement therapy, than CEDVI measured by a modified PAC.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EFFECTS OF DOXA.CURIUM CHLORIDE ON BIVENTRICULAR CARDIAC FUNCTION IN PATIENTS WITH CARDIAC DISEASEf

Doxacurium chloride (BW A938U) (Nuromax) is a new non-depolarizing neuromuscular blocking drug with a duration of action similar to that of pancuronium. Its ED95 is 30 fig kg" , and it does not release histamine in doses as high as 80 |ig kg" [1]. The cardiovascular stability of doxacurium has been demonstrated in healthy patients [2], and in patients anaesthetized with sufentanil and midazolam...

متن کامل

Comparison of Doppler flow Tei-indexes with pulmonary artery thermodilution measurement of cardiac output in an experimental porcine model.

The objective of our study was to compare Doppler echocardiography imaging with pulmonary artery thermodilution measurement during mechanical ventilation. Total 78 piglets (6 weeks old, average weight 24 kg, under general anesthesia) were divided into 4 groups under different cardiac loading conditions (at rest, with increased left ventricular afterload, with increased right ventricular preload...

متن کامل

Transoesophageal Doppler echocardiographic measurement of cardiac output by the mitral annulus method.

OBJECTIVE To compare cardiac output measured by the transoesophageal Doppler and thermodilution techniques. DESIGN Prospective direct comparison of paired measurements by both techniques in each patient. SETTING Intensive care unit in a cardiovascular centre. PATIENTS 65 patients after open heart surgery (mean (SD) age 53 (12) years). INTERVENTIONS Cardiac output was measured simultaneo...

متن کامل

Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting.

BACKGROUND AND OBJECTIVE During off-pump coronary bypass grafting, surgical manipulation and dislocation of the heart may cause cardiovascular instability. Monitoring of cardiac output facilitates intraoperative haemodynamic management but pulmonary artery catheters are often considered too invasive. Pulse contour analysis and transoesophageal echocardiography could serve as alternatives, but t...

متن کامل

On-line estimation of left ventricular stroke volume using transoesophageal echocardiography and acoustic quantification.

We have examined the usefulness of transoesophageal echocardiography (TOE) and automated endocardium detection for on-line calculation of left ventricular stroke volume. In 12 of 15 patients undergoing abdominal surgery, stroke volume was derived continuously from the multiple discs (MD) and area-length (AL) methods and compared with stroke volume calculated by thermodilution. In 10 patients (8...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 94 6  شماره 

صفحات  -

تاریخ انتشار 2005