Optical coherence tomography accurately measures corneal power change from laser refractive surgery.

نویسندگان

  • Ryan P McNabb
  • Sina Farsiu
  • Sandra S Stinnett
  • Joseph A Izatt
  • Anthony N Kuo
چکیده

PURPOSE To determine the ability of motion-corrected optical coherence tomography (OCT) to measure the corneal refractive power change due to LASIK. DESIGN Evaluation of a diagnostic test or technology in a cohort. SUBJECTS A total of 70 eyes from 37 subjects undergoing LASIK were measured preoperatively. A total of 39 eyes from 22 subjects were measured postoperatively and completed the study. METHODS Consecutive patients undergoing LASIK at the Duke Eye Center who consented to participate were imaged with Placido-ring topography, Scheimpflug photography, and OCT on the day of their surgery. Patients were then reimaged with the same imaging systems at the postoperative month 3 visit. Change in preoperative to postoperative corneal refractive power as measured by each of the imaging modalities was compared with the preoperative to postoperative change in manifest refraction (MRx) using the t test with generalized estimating equations. MAIN OUTCOME MEASURES Corneal refractive power change due to LASIK as measured by Placido-ring topography, Scheimpflug photography, and OCT compared with the MRx change vertexed to the corneal plane. The change in MRx should correspond to the change in the corneal refractive power from LASIK and was considered the reference measurement. RESULTS In 22 individuals (39 eyes) returning after LASIK, we found no significant difference between the clinically measured pre- to post-LASIK change in MRx and both Scheimpflug photography (P = 0.714) and OCT (P = 0.216). In contrast, keratometry values from Placido-ring topography were found to be significantly different from the measured refractive change (P < 0.001). In addition, of the 3 imaging modalities, OCT recorded the smallest mean absolute difference from the reference measurement with the least amount of variability. CONCLUSIONS Motion-corrected OCT more accurately measures the change in corneal refractive power due to laser refractive surgery than other currently available clinical devices. By offering accurate corneal refractive power measurements in normal and surgically modified subjects, OCT offers a compelling alternative to current clinical devices for determining corneal refractive power.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of Optical Coherence Tomography on Corneal Surface Laser Ablation

This paper focuses on reviewing the roles of optical coherence tomography (OCT) on corneal surface laser ablation procedures. OCT is an optical imaging modality that uses low-coherence interferometry to provide noninvasive cross-sectional imaging of tissue microstructure in vivo. There are two types of OCTs, each with transverse and axial spatial resolutions of a few micrometers: the time-domai...

متن کامل

Laboratory evaluation of selective in situ refractive cornea collagen shrinkage with continuous wave infrared laser combined with transepithelial collagen cross-linking: a novel refractive procedure

BACKGROUND This research comprised a laboratory evaluation of a novel refractive surgery technique involving sequential corneal subsurface shrinkage-driven reshaping using a continuous wave mid-infrared laser application followed by stiffening via rapid transepithelial higher fluence collagen cross-linking for shape persistence/longevity on cadaver corneas. MATERIALS AND METHODS Ten cadaver c...

متن کامل

Posterior corneal astigmatism.

In the optical system of the human eye, total refractive power consists mainly of corneal and lenticular components. Approximately two-thirds of the eye's converging power is at the air–cornea (tear film) interface; one-third is in the lens. Total corneal power is determined by corneal anterior and posterior curvature, corneal thickness, and the corneal refractive indices. Traditionally, anteri...

متن کامل

Long-term outcomes after mechanized arcuate keratotomy for the correction of astigmatism after keratoplasty.

The management of high postoperative astigmatism remains a major challenge for corneal refractive surgeons and various techniques have been evaluated.1 The recent introduction and development of femtosecond laser-assisted keratotomy could potentially combine a wide range of corrections with the accuracy and safety of laser treatment.2,3 Assessing the long-term visual and keratometric outcomes o...

متن کامل

Effects of Laser Physical Parameters on Lesion Size in Retinal Photocoagulation Surgery: Clinical OCT and Experimental Study

Introduction: The aim of the present study was to determine burn intensity in retinal laser photocoagulation based on laser parameters; wavelength, power, beam size and pulse duration, using Optical Coherence Tomography (OCT), fundus camera, physical eye model and computer simulation in a clinical study.Materials and Methods: Participants were 10 adult patients between 50-80 years with prolifer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ophthalmology

دوره 123 1  شماره 

صفحات  -

تاریخ انتشار 2015