Kendrick mass defect spectrum: a compact visual analysis for ultrahigh-resolution broadband mass spectra.
نویسندگان
چکیده
At currently achievable Fourier transform ion cyclotron resonance broadband mass spectrometry resolving power (m/deltam50% > 350,000 for 200 < m/z < 1,000), it would be necessary to spread out a conventional mass spectrum over approximately 200 m in order to provide visual resolution of the most closely resolved peaks. Fortunately, there are natural gaps in a typical mass spectrum, spaced 1 Da apart, because virtually no commonly encountered elemental compositions yield masses at those values. Thus, it is possible to break a broadband mass spectrum into 1-Da segments, rotate each segment by 90 degrees, scale each segment according to its mass defect (i.e., difference between exact and nominal mass), and then compress the spacing between the segments to yield a compact display. For hydrocarbon systems, conversion from IUPAC mass to "Kendrick" mass (i.e., multiplying each mass by 14.00000/14.01565) further simplifies the display by rectilinearizing the peak patterns. The resulting display preserves not only the "coarse" spacings (e.g., approximately 1 Da between odd and even masses, corresponding to either even vs odd number of nitrogens or 12C(c) vs 12C(c-1)13C1 elemental compositions of the same molecule; approximately 2-Da separations, corresponding to a double bond or ring; approximately 14 Da separations, corresponding to one CH2 group) but also the "fine structure" (i.e., different mass defects for different elemental compositions) across each 1-Da segment. The method is illustrated for experimental electrospray ionization FTICR ultrahigh-resolution mass spectra of a petroleum crude oil. Several thousand elemental compositions may be resolved visually in a single one-page two-dimensional display, and various compound families-class (NnOoSs), type (Z in C(c)H2(c+z)NnOoSs), and alkylation series-may be identified visually as well.
منابع مشابه
Structural Characterization of Polymers by MALDI Spiral-TOF Mass Spectrometry Combined with Kendrick Mass Defect Analysis
High-resolution mass spectrometry (HRMS) continues to play an important role in the compositional characterization of larger organic molecules. In the field of polymer characterization, however, the application of HRMS has made only slow progress because of lower compatibility between matrix-assisted laser desorption/ionization (MALDI) and ultrahigh-resolution Fourier transform ion cyclotron re...
متن کاملMALDI SpiralTOF high‐resolution mass spectrometry and Kendrick mass defect analysis applied to the characterization of poly(ethylene‐co‐vinyl acetate) copolymers
RATIONALE Poly(ethylene-co-vinyl acetate) copolymers - usually referred to as EVA - are first class industrial polymers used for applications ranging from padding to photovoltaics as encapsulant for the silicon solar cells. Various techniques have been used for their characterization but the analysis of intact EVA chains using mass spectrometry (MS) has not been reported so far. METHODS Three...
متن کاملImproving the Resolution of Kendrick Mass Defect Analysis for Polymer Ions with Fractional Base Units
The concept of a fractional base unit for the Kendrick mass defect (KMD) analysis of polymer ions is introduced for the first time. A fraction of the ethylene oxide (EO) repeat unit (namely EO/8) has been used for the KMD analysis of a poly(ethylene oxide) and found to amplify the variations of KMD between monoisotopic and 13C isotopes, producing an isotopically resolved KMD plot at full scale ...
متن کامل63-67 3번 Sunghwan Kim(Reveiw).fm
The need of heavy and unconventional crude oil as an energy source is increasing day by day, so does the importance of petroleomics: the pursuit of detailed knowledge of heavy crude oil. Crude oil needs techniques with ultra-high resolving capabilities to resolve its complex characteristics. Therefore, ultra-high resolution mass spectrometry represented by Fourier transform ion cyclotron resona...
متن کاملA New Hybrid Feature Subset Selection Algorithm for the Analysis of Ovarian Cancer Data Using Laser Mass Spectrum
Introduction: Amajor problem in the treatment of cancer is the lack of an appropriate method for the early diagnosis of the disease. The chemical reaction within an organ may be reflected in the form of proteomic patterns in the serum, sputum, or urine. Laser mass spectrometry is a valuable tool for extracting the proteomic patterns from biological samples. A major challenge in extracting such ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 73 19 شماره
صفحات -
تاریخ انتشار 2001