Implantation of additional subcutaneous array electrode reduces defibrillation threshold in ICD patients – preliminary results

نویسندگان

  • Maciej Kempa
  • Szymon Budrejko
  • Łukasz Drelich
  • Tomasz Królak
  • Grzegorz Raczak
  • Dariusz Kozłowski
چکیده

INTRODUCTION Among the recipients of implantable cardioverter-defibrillators (ICDs), there is a group of patients in whom the defibrillation threshold (DFT) is too high to enable a sufficient safety margin between the DFT and the maximal available output of the device. The aim of the study was to investigate the ability of an additionally implanted single-coil subcutaneous array electrode to reduce the DFT in such patients. MATERIAL AND METHODS Medtronic 6996SQ electrode was implanted in 15 patients selected from our follow-up group of 741 ICD patients: 10 of them had insufficient post-implant DFT safety margin, and 5 had ineffective first maximal energy shock as recorded by the device. In 6 cases the patients had CRT-D devices, in 5 cases - dual-chamber ICDs, and in 4 cases - single-chamber ICDs. In all patients but one the defibrillating electrode was single-coil. In one patient it was dual-coil. The underlying disease was coronary artery disease in 10 patients, dilated cardiomyopathy in 4 patients and hypertrophic cardiomyopathy in 1 patient. RESULTS The subcutaneous electrode was successfully implanted in all the patients qualified for the procedure. No technical issues or perioperative complications were observed. Mean DFT was reduced from 33.3 ±4.1 J before the procedure to 25.3 ±4.4 J after the implantation procedure (p < 0.01). CONCLUSIONS Our results show that the use of a single-coil subcutaneous electrode to reduce the DFT is a safe and effective procedure. Further studies are necessary to confirm these results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantation of additional defibrillation lead into the coronary sinus: an effective method of decreasing defibrillation threshold.

We report a case of successful implantation of an additional defibrillation lead into the coronary sinus due to high defibrillation threshold (DFT) in a seriously ill patient with a history of extensive myocardial infarction referred for implantable cardioverter- defibrillator implantation after an episode of unstable ventricular tachycardia. All previous attempts to reduce DFT, including subcu...

متن کامل

High defibrillation threshold in patients with implantable defibrillator: how effective is the subcutaneous finger lead?

OBJECTIVE Even in the era of high output implantable cardioverter defibrillator (ICD) devices, a certain proportion of patients cannot be successfully defibrillated with 10 J safety margin. In practice, either the use of a single- or double-coil lead does not guarantee successful termination of induced ventricular fibrillation. Therefore, we investigated the effectiveness of the subcutaneous fi...

متن کامل

Subcutaneous Implantable Cardioverter Defibrillators Implantation Without Defibrillation Threshold Testing: A Single Center Experience

Background Subcutaneous implantable cardioverter defibrillator (S-ICD) system has been proven to be an effective therapy for prevention of sudden cardiac death (SCD) in selected patients. Although the Shockless IMPLant Evaluation (SIMPLE) trial has shown that defibrillation threshold (DFT) testing is not necessary for transvenous ICD (TV-ICD) systems, it is still recommended for S-ICD systems. ...

متن کامل

Critical analysis of ineffective post implantation implantable cardioverter-defibrillator-testing

AIM To test of the implantable-cardioverter-defibrillator is done at the time of implantation. We investigate if any testing should be performed. METHODS All consecutive patients between January 2006 and December 2008 undergoing implantable cardioverter-defibrillator (ICD) implantation/replacement (a total of 634 patients) were included in the retrospective study. RESULTS Sixteen patients (...

متن کامل

Successful intermuscular implantation of subcutaneous implantable cardioverter defibrillator in a Japanese patient with pectus excavatum

The entirely subcutaneous implantable cardioverter-defibrillator (ICD) system was developed to provide a life-saving defibrillation therapy that does not affect the heart and vasculature. The subcutaneous ICD is preferred over the transvenous ICD for patients with a history of recurrent infection presenting major life-threatening rhythms. In this case report, we describe the first successful in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2013