Changes in transient-evoked otoacoustic emission levels with negative tympanometric peak pressure in infants and toddlers.

نویسندگان

  • Beth A Prieve
  • Lauren Calandruccio
  • Tracy Fitzgerald
  • Annette Mazevski
  • Lea M Georgantas
چکیده

OBJECTIVES Otoacoustic emission (OAE) testing is now a standard component of the diagnostic audiology protocol for infants and toddlers and is an excellent tool for detecting moderate-to-profound cochlear hearing loss. Detection of hearing loss is especially important in infants and toddlers. Unfortunately, middle-ear dysfunction has a high incidence in this age range and can confound interpretation of OAEs. The goal of the study was to determine how transient-evoked otoacoustic emission (TEOAE) and noise levels were different when tympanometric peak pressures (TPP) measured from tympanograms were normal versus negative in the same individual. Another goal was to determine how TEOAE screening pass rates using a priori pass criteria were affected on days when TPP was negative. DESIGN TEOAE and noise levels were collected in 18 cases under 2 conditions: on a day when the tympanogram TPP was normal and on a day when the tympanogram TPP was negative. Data were collected from 11 children aged 3 to 39 mo, some of whom were tested more than once. Paired t tests were performed to determine whether there were changes in overall TEOAE and noise levels and TEOAE and noise levels analyzed into half-octave bands. A one-way ANOVA was performed on differences across half-octave bands to determine whether TPP affected TEOAE levels for some frequency bands more than others. Equality-of-proportion Z tests were run to determine whether there were significant differences in the percentage of "passes" on days when TPP was negative and TPP was normal. RESULTS Mean TEOAE level was lower when TPP was negative, but noise levels did not change between the 2 conditions. Mean TEOAE levels were lower for all frequency bands from 1000 to 4000 Hz and no significant differences were found among the mean reduction across frequency bands. There were no significant differences in the percentage of passes between TEOAEs collected on days when TPP was normal and when TPP was negative. CONCLUSIONS Mean data indicated that when tympanograms had negative TPP, TEOAE level was lower by approximately 4 dB across all frequency bands. However, this affected the pass rate in only 5% to 6% of cases. Although the number of participants in the current study was small, the data suggest that it is possible to measure TEOAEs in children with negative TPP. If emission-to-noise ratio is used to identify hearing loss in mid-to-high frequency bands, the majority of children will still have TEOAEs that meet clinical criteria, this providing the clinician with important information about cochlear status.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Distortion and Transient Evoked Otoacoustic Emission in Tinnitus Patients with Normal Hearing

Introduction: Tinnitus is a perception of sound without external source. The exact etiology of tinnitus is not fully understood, although some researchers believe that the condition usually starts in the cochlea. The aim of this study was to determine the potential contribution of outer hair cell dysfunction to chronic tinnitus, by application of Distortion-Product Evoked Otoacoustic Emission (...

متن کامل

Multifrequency tympanometry in infants

INTRODUCTION  The use of conventional tympanometry is not sufficiently sensitive to detect all cases of middle ear changes, and this hinders accurate diagnosis. OBJECTIVE  To characterize acoustic immittance measures of infants from 0 to 3 months of age using multifrequency tympanometry in a prospective study. METHOD  54 infants from 0 to 3 months of age were evaluated. The inclusion criter...

متن کامل

High Frequency Tympanometry (1,000 Hz) for Neonates with Normal and Abnormal Transient Evoked Otoacoustic Emissions

BACKGROUND AND OBJECTIVES This paper aimed at evaluating the characteristics of high-frequency (1,000 Hz) acoustic admittance (ya) for the neonates with transient evoked otoacoustic emissions (TEOAE) as either pass or refer group. SUBJECTS AND METHODS Using a 1,000 Hz probe tone, 297neonates (152 male, 145 female aged 0-104 days old) were evaluated. Tympanometric parameters admittance value a...

متن کامل

Investigation of the results of infant hearing screening test with transient evoked otoacoustic emissions in Moradi Hospital of Rafsanjan, Iran, in 2014

Background: Congenital hearing loss delays many aspects of a child's development, including speech and socio-cognitive development. The aim of this study was determine the results of infant hearing screening with transient evoked otoacoustic emission (TEOAE) in Moradi Hospital, Rafsanjan, Iran: 2014. Materials and Methods: In this descriptive cross-sectional study from 6017 infants born in Nik...

متن کامل

Wideband reflectance in newborns with present transient-evoked otoacoustic emissions.

PURPOSE To characterize the normal values of acoustic energy reflectance obtained with pure-tone stimulation in neonates prior to hospital discharge. METHODS Seventy-seven infants (37 girls and 40 boys) were evaluated by measuring acoustic reflectance using pure-tone stimuli, transient-evoked otoacoustic emissions, and tympanometric probe frequencies of 226 Hz and 1 kHz. RESULTS At low freq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ear and hearing

دوره 29 4  شماره 

صفحات  -

تاریخ انتشار 2008