Ultrasonographic assessment of inferior vena cava/abdominal aorta diameter index: a new approach of assessing hypovolemic shock class 1.

نویسندگان

  • Nik Hisamuddin Na Rahman
  • Rashidi Ahmad
  • Meera Mohaideen Kareem
  • Mohammad Iqhbal Mohammed
چکیده

BACKGROUND We designed this study to expand the usage of ultrasound to detect early occurrence of hypovolemia. We explore the potential use of inferior vena cava (IVC) and abdominal aorta (AA) diameter index (IVC:AA) measured ultrasonographically to detect class 1 hypovolemic shock with blood loss less than 15%.ᅟ METHODS The aim of this study was to determine the changes in the diameter of inferior vena cava and abdominal aorta in blood donors by using ultrasound, pre and post blood donation. The result of the study would be further explorated to determine the inferior vena cava (IVC) abdominal aorta (Aorta) diameter index (IVC:Aorta). This was a prospective study done in the blood bank of a university hospital. Researcher was trained by a senior radiologist to assess inferior vena cava and abdominal aorta diameter. Fifty-two healthy blood donors were included in the study. Inclusion criteria were same with the blood bank criteria to donate blood. Demographic data and vital signs were taken before the ultrasound measurement done for inferior vena cava and abdominal aorta diameter. Once the volunteers donated their blood of approximately 450 mls; the measurements were repeated using the same methods. RESULTS There were differences in IVC, abdominal aorta and inferior vena cava:aorta diameters index pre and post donation. With mathematical analysis, we suggested the number of IVC:Aorta index as 1.14±2SD with SD 0.18 as a cut off value for class 1 hypovolemic shock. CONCLUSION The IVC:Aorta diameter index can be used as a parameter for detecting early phase (Class 1) of hypovolemic shock.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasonographic Assessment of Caudal Vena Cava to Aorta Ratio as a Novel Endpoint in Hemorrhagic Shock Resuscitation in Dogs

Objective- The aim of this study was to assess ultrasonography-derived caudal vena cava to aorta ratio (CVC/Ao) as a novel endpoint in the resuscitation of experimental hemorrhagic shock in dogs. Design- Experimental study. Animals- Ten adult mongrel healthy dogs. Procedures- After induction of anesthesia (con...

متن کامل

Correlation of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index with Central Venous Pressure in Diagnosis and Management of Neonatal Shock

Background: Neonatal intensive care unit (NICU)Conventionally, Central Venous Pressure (CVP) monitoring has beenused by intensivists to measure intravascular volume. However, it is an invasive procedure resulting in many complications. Non-invasive ultrasonographic measurement of inferior vena cava collapsibility index (IVC-CI) is a promising alternative. Therefore, this study wasconducte...

متن کامل

The efficacy of inferior vena cava diameters and the jugular vein in assessing fluid resuscitation

Objective: Fluid resuscitation is necessary in almost all critical patients. The central venous pressure (CVP) is a well-established method of assessing resuscitation. Recently, there have been attempts to investigate less invasive methods like the diameters of inferior vena cava (IVC) or the jugular vein. We aimed to investigate this method in our research.Methods: Seventy eight critical...

متن کامل

Inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults

The assessment of the body fluid status is one the most challenging tasks in clinical practice. Although there are many methods to assess the body fluid status of patients, none of them is fully satisfactory in contemporary medical sciences. In the article below, we compare the results of measurements performed by experienced and inexperienced examiners based on the inferior vena cava/aorta dia...

متن کامل

Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status

UNLABELLED Appropriate hydration is a very important prognostic factor for the patient's health. Ultrasonographic assessment of hydration status is rarely used in pediatric medicine and it is not used at all in neonates due to the fact that no reference values have been established for this age group. The aim of the paper was to establish reference values for neonates. MATERIAL AND METHODS Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of emergency medicine

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 2016