Intraocular implants: the postoperative astigmatism.

نویسنده

  • J G Moore
چکیده

A series of 100 cases of intraocular implants has been considered, especially with regard to the postoperative astigmatism. This was found to be far higher than in a similar series of cases subjected to the same techniques without an implant. The operative results appear to be as good as in any conventional series, except for 2 cases. The reason for the excessive astigmatism (average 2.84 D) is not clear but the following factors have been suggested: (1) faulty surgical technique, that is, irregular corneal healing; (2) astigmatic errors in the actual intraocular lens itself; (3) tilting of the intraocular lens; (4) the intraocular lens, owing to its own inherent weight, may pull on the iris and ciliary body and even distort the cornea on healing. A summation of all these factors could produce an undesirably high degree of astigmatism.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of NIDEK OPD Scan II wavefront aberrometry in toric intraocular lens implantation.

PURPOSE To present case examples outlining the use of wavefront aberrometry for toric intraocular lens (IOL) implantation pre- and postoperatively. METHODS Twelve eyes that underwent AcrySof Toric IOL (Alcon Inc Laboratories) implantation were assessed pre- and postoperatively using the NIDEK OPD Scan II (NIDEK Co Ltd). Wavefront aberrometry, corneal topography, and objective visual quality w...

متن کامل

Rotational stability of the AcrySof SA60TT toric intraocular lenses: A cohort study

BACKGROUND To evaluate the rotational stability of the three types of AcrySof SA60TT toric intraocular lenses (Alcon, Switzerland) in cataract surgery after the first postoperative week. METHODS A retrospective study of 44 eyes in 33 patients. All patients underwent similar uncomplicated phacoemulsification cataract surgery. Seven eyes with corneal astigmatism of less than 1.5 D were implante...

متن کامل

Tecnis Symfony Intraocular Lens with a “Sweet Spot” for Tolerance to Postoperative Residual Refractive Errors

Purpose: To investigate the impact of residual astigmatism on visual acuity (VA) after the implantation of a novel extended range of vision (ERV) intraocular lens (IOL) based on the correction of spherical and chromatic aberration. Method: The study enrolled 411 patients bilaterally implanted with the ERV IOL Tecnis Symfony. Visual acuity and subjective refraction were analyzed during the 4to 6...

متن کامل

Acrylic toric intraocular lens implantation: a single center experience concerning clinical outcomes and postoperative rotation

PURPOSE To present clinical results of toric intraocular lens (IOL) implantation for preexisting astigmatism correction and determine the time of any postoperative rotation. PATIENTS AND METHODS Twenty-nine eyes of 19 patients underwent uncomplicated phacoemulsification and were implanted with an Acrysof ((c)) toric IOL. Uncorrected visual acuity, residual astigmatism, and postoperative rotat...

متن کامل

Effects of preoperative corneal astigmatism orientation on results with a low-cylinder-power toric intraocular lens.

PURPOSE To evaluate refractive results with a low-cylinder-power toric intraocular lens (IOL) and the effect of preoperative corneal astigmatism orientation on results. SETTING Private practice, Jackson, Michigan, USA. DESIGN Comparative case series. METHODS This retrospective review of clinical records comprised patients with 0.75 to 1.38 diopters (D) of preoperative corneal astigmatism ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 64 5  شماره 

صفحات  -

تاریخ انتشار 1980