Four-component model of body composition in chronic renal failure comprising dual-energy X-ray absorptiometry and measurement of total body water by deuterium oxide dilution.

نویسندگان

  • G Woodrow
  • B Oldroyd
  • J H Turney
  • P S Davies
  • J M Day
  • M A Smith
چکیده

1. Assessment of nutrition in patients with chronic renal failure by body composition measurement techniques may be affected by variable hydration. 2. This study aimed to derive a four-component model of body composition (consisting of fat, protein, total body water and body mineral) from a combination of dual-energy X-ray absorptiometry and total body water measured by deuterium oxide dilution, allowing assessment of body protein stores without the effect of variation in hydration. Patients with chronic renal failure on haemodialysis, peritoneal dialysis and conservative treatment and a control group were studied. Patients with chronic renal failure were at an 'ideal' state of hydration on clinical assessment. 3. Hydration was defined by total body water as a percentage of fat-free mass measured by dual-energy X-ray absorptiometry, and no differences were found between chronic renal failure subgroups and control subjects (except in the female undialysed chronic renal failure subgroup). Hydration was significantly correlated with percentage total body fat in the control groups but not in patients with chronic renal failure. 4. Lean tissue measured by dual-energy X-ray absorptiometry was significantly reduced in three of the six chronic renal failure groups compared with control subjects (male and female patients on haemodialysis and female patients on peritoneal dialysis). Protein estimated from the four-component model failed to detect these abnormalities. 5. Lean tissue measured by dual-energy X-ray absorptiometry in normal subjects strongly correlated with fat-free mass measured by total body potassium in normal subjects (male r = 0.91; female r = 0.89, both P < 0.0001). The correlation of protein estimated from the four-component model with fat-free mass measured by total body potassium was far weaker in male control subjects (r = 0.51, P < 0.05) and not significant in female control subjects (r = 0.38, P not significant). In the normal subjects protein estimated from the four-component model showed a much greater variation from protein estimated by total body potassium than did protein estimated simply as 27% of dual-energy X-ray absorptiometry fat-free mass minus total body mineral. 6. Hydration in patients with chronic renal failure in whom fluid balance is believed to be normal on clinical criteria does not differ from that in normal subjects. The combined model of dual-energy X-ray absorptiometry and total body water is not a useful method for the measurement of body protein.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo validation of whole body composition estimates from dual-energy X-ray absorptiometry.

We validated whole body composition estimates from dual-energy X-ray absorptiometry (DEXA) against estimates from a four-component model to determine whether accuracy is affected by gender, race, athletic status, or musculoskeletal development in young adults. Measurements of body density by hydrostatic weighing, body water by deuterium dilution, and bone mineral by whole body DEXA were obtaine...

متن کامل

Comparison of DXA and water measurements of body fat following gastric bypass surgery and a physiological model of body water, fat, and muscle composition.

Measurement of body composition changes following bariatric surgery is complicated because of the difficulty of measuring body fat in highly obese individuals that have increased photon absorption and are too large for the standard dual-energy X-ray absorptiometry (DXA) table. We reproducibly measured body composition from half-body DXA scans and compared the values of total body fat estimated ...

متن کامل

Validation of estimates of total body water in pediatric dialysis patients by deuterium dilution.

BACKGROUND Current K-DOQI recommendations call for an assessment of dialysis adequacy that depends critically on an estimate of total body water (TBW). Such estimates are problematic in children since the range of patient size is large, and often formulas derived in normals are not validated in end-stage renal disease. Gold standard methods of TBW measurement, such as deuterium dilution ((2)H(2...

متن کامل

Four-component model for the assessment of body composition in humans: comparison with alternative methods, and evaluation of the density and hydration of fat-free mass.

1. Body composition was assessed in 28 healthy subjects (body mass index 20-28 kg/m2) by dual-energy X-ray absorptiometry, deuterium dilution, densitometry, 40K counting and four prediction methods (skinfold thickness, bioelectrical impedance, near-i.r. interactance and body mass index). Three- and four-component models of body composition were constructed from combinations of the reference met...

متن کامل

Fat mass deposition during pregnancy using a four-component model.

Estimates of body fat mass gained during human pregnancy are necessary to assess the composition of gestational weight gained and in studying energy requirements of reproduction. However, commonly used methods of measuring body composition are not valid during pregnancy. We used measurements of total body water (TBW), body density, and bone mineral content (BMC) to apply a four-component model ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical science

دوره 91 6  شماره 

صفحات  -

تاریخ انتشار 1996