Benchmarking adult CT-dose levels to regional and national references using a dose-tracking software: a multicentre experience
نویسندگان
چکیده
OBJECTIVES To benchmark CT-dose data for standard adult CT studies to regional and national reference levels using a dose-tracking system. METHODS Data from five CT systems from three hospitals were collected over a 1- to 2.5-year period (2012-2014), using the same type of dose management system. Inclusion criteria were adult patients and standard CT-head, CT-abdomen-pelvis, CT-thorax, CT-lumbar spine, CT-pulmonary embolism, CT-cervical spine and CT-thorax-abdomen studies, with one helical scan. Volumetric CT-dose index (CTDIvol), dose length product (DLP) and scan length from 31,709 scans were analysed statistically. RESULTS After dose optimisation CTDIvol and DLP values were below the national diagnostic reference levels (DRLs) for all CT studies and for all systems investigated. Mostly no significant differences were found between CTDIvol and DLP levels (p values ≥ 0.01) of CT studies performed on different scanners within the same hospital. Significant dose differences (p values < 0.01) were instead observed among hospitals for comparable CT studies. Dose level range and scan length differences for similar CT studies were revealed. CONCLUSIONS Dose-tracking systems help to reduce CT-dose levels below national DRLs. However, dose and protocol data comparison between and within hospitals has the potential to further reduce variability in dose data of standard adult CT studies. KEY POINTS • Retrospective three-centre study on dose levels of standard adult CT procedures. • Dose-tracking systems help hospitals to stay below national dose reference levels. • Dose-tracking systems help to align CT dose levels between scanners within hospitals. • Benchmarking shows CT dose level variability for similar examinations in different hospitals. • Differences in dose level range/scan length for similar CT studies are revealed.
منابع مشابه
Assessment and evaluation of patient doses in adult common CT examinations towards establishing national diagnostic reference levels
Background: Patient radiation doses from computed tomography (CT) are increasing due to the number of CT examinations performed every day. The aim of this study was assess and evaluate patient radiation doses for adult’s common CT examinations to derive local diagnostic guidance levels for common CT examinations. Materials and Methods: Volume and weighted computed tomography dose index (C...
متن کاملDiagnostic Reference Level of Computed Tomography Examinations and Need for Dose Optimization in Ondo State, Nigeria
Introduction: The present study was conducted to obtain State diagnostic reference levels (DRLs) of five routine computed tomography (CT) examinations from two CT centers in Ondo State and to identify factors responsible for dose variation and escalation in these CT centers. Material and Methods: Acquisition parameters and CT dose indices wer...
متن کاملبررسی دز مؤثر دریافتی بیماران در تصویربرداری استخوان تمام بدن به روش اسپکت-سی تی ناشی از تصویربرداری عبوری، در بخش پزشکی هستهای بیمارستان دکتر شریعتی
Introduction: whole body bone scan is one of the most useful procedures of nuclear medicine. Accurate distribution of radiopharmaceutical is yielded by using SPECT-CT. There are concerns about the radiation dose of CT part. The present study aimed to evaluate the patients’ dose in bone nuclear medicine imaging. Methods and Materials: First of all, the dose report of CT console was calibrated u...
متن کاملPediatric dose assessment in common CT examination towards establishment of related regional DRL in Mazandaran, Iran
Background: Computed Tomography (CT) is main contributor of population dose from diagnostic X-ray examinations. Children are more radiosensitive than adults, thus optimization of CT examination in these patients is essential. The purpose of this study was to evaluate dose delivered to pediatric patients’ undergoing CT examination of the common examinations and also establishing local Diag...
متن کاملDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
متن کامل