The effects of crystalloid and colloid preload on cardiac output in the parturient undergoing planned cesarean delivery under spinal anesthesia: a randomized trial.
نویسندگان
چکیده
BACKGROUND Hypotension after spinal anesthesia for cesarean delivery remains a major clinical problem. Fluid preloading regimens together with vasopressors have been used to reduce its incidence. Previous studies have used noninvasive arterial blood pressure measurement and vasopressor requirements to evaluate the effect of preload. We used a suprasternal Doppler flow technique to measure maternal cardiac output (CO) and corrected flow time (FTc, a measure of intravascular volume) before and after spinal anesthesia after 3 fluid preload regimens. We hypothesized that colloid solutions, compared with crystalloid, would produce the largest increase in CO and have the lowest incidence of hypotension. METHODS Sixty healthy term women scheduled for planned cesarean delivery under spinal anesthesia were recruited for this randomized, double-blind study. Baseline heart rate, systolic blood pressure (SBP), CO, and FTc were recorded in the left lateral tilt position. Patients were randomized to receive 1 of 3 fluid preload regimens given over 15 min: 1.5 L crystalloid (Hartman's solution), 0.5 L of 6% w/v hydroxyethyl starch (HES) solution (HES 0.5), or 1 L of 6% w/v HES solution (HES 1.0). Further measurements were made after fluid loading every 5 min for 30 min. After 30 min, spinal anesthesia was induced with hyperbaric bupivacaine 12.5 mg with fentanyl 15 microg and recordings were continued every 5 min for 20 min or until surgery started. The primary outcome, CO, was compared among groups. The incidence of hypotension (defined as a 20% reduction in SBP from the baseline), ephedrine use, and umbilical cord blood gases were also compared. RESULTS Patient characteristics, heart rate, SBP, and cord gases were similar among groups. Although CO and FTc increased after preload in all groups (P < 0.005), this was only maintained with HES 1.0 after spinal anesthesia (P < 0.005). There were no differences among groups in the incidence of hypotension (70% vs 35% vs 65% for Hartman's solution, HES 0.5, and HES 1.0, respectively; P = 0.069) or mean ephedrine dose (10.4 vs 5.7 vs 9.7 mg; P = 0.26). CONCLUSION Despite CO and FTc increases after fluid preload, particularly with HES 1.0 L, hypotension still occurred. The data suggest that CO increases after these preload regimens cannot compensate for reductions in arterial blood pressure after spinal anesthesia.
منابع مشابه
Crystalloid and colloid preload for maintaining cardiac output in elderly patients undergoing total hip replacement under spinal anesthesia
The aim of the present study was to compare the effects of colloid and crystalloid preload on cardiac output (CO) and incidence of hypotension in elderly patients under spinal anesthesia (SA). A randomized, double-blinded study was conducted including 47 elderly patients undergoing scheduled total hip replacement (THR), who were randomized to three groups: the control group (C group, n = 15), c...
متن کاملمقایسهی اثرات تجویز کلوئید قبل و بعد ازآنستزی اسپاینال Co-Loading)و (Pre-Loadingدر پیشگیری از هیپوتانسیون مادران دراعمال سزارین
Background and Objective: Hypotension associated with spinal anesthesia for cesarean section is still a clinical problem. The role of crystalloid preloading to prevent hypotension associated with spinal anesthesia in parturients during cesarean section has been challenged. However, studies with crystalloids predict that fluid loading should be more efficacious if administered immediately after ...
متن کاملThe effects of an increase of central blood volume before spinal anesthesia for cesarean delivery: a qualitative systematic review.
UNLABELLED We evaluated in this qualitative systematic review the efficacy of increasing central blood volume on the incidence of hypotension after spinal anesthesia for elective cesarean delivery. Randomized controlled trials investigating any method of increasing central blood volume before the initiation of obstetric spinal anesthesia were sought by using MEDLINE (1966-2000), Embase (January...
متن کاملA randomized comparative trial of combinational methods for preventing post-spinal hypotension at elective cesarean delivery*
BACKGROUND Various methods have been applied to prevent maternal hypotension after spinal anesthesia for cesarean delivery. We compared the efficacy of three combinational methods in this regard in the current study. METHODS In this randomized comparative trial, 150 candidates of elective cesarean delivery under spinal anesthesia were assigned to three groups: crystalloid preload and leg band...
متن کاملThe Effect of Prophylactic Infusion of Combined Ephedrin and Phenylephrine on Maternal Hemodynamic after Spinal Anesthesia for Cesarean Section: A Randomized Clinical Trial
Several techniques have been proposed to prevent hypotension in obstetric patients. Ephedrine and phenylephrine are individually used to prevent maternal hypotension; however, each has its own drawbacks. Some researchers have reported that the infusion of combined ephedrine and phenylephrine immediately after spinal anesthesia for cesarean delivery reduces the incidence of maternal hypotension....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesia and analgesia
دوره 109 6 شماره
صفحات -
تاریخ انتشار 2009