Effective dose conversion coefficients for radionuclides exponentially distributed in the ground

نویسندگان

  • Kimiaki Saito
  • Nobuhito Ishigure
  • Nina Petoussi-Henss
  • Helmut Schlattl
چکیده

In order to provide fundamental data required for dose evaluation due to environmental exposures, effective dose conversion coefficients, that is, the effective dose rate per unit activity per unit area, were calculated for a number of potentially important radionuclides, assuming an exponential distribution in ground, over a wide range of relaxation depths. The conversion coefficients were calculated for adults and a new-born baby on the basis of dosimetric methods that the authors and related researchers have previously developed, using Monte Carlo simulations and anthropomorphic computational phantoms. The differences in effective dose conversion coefficients due to body size between the adult and baby phantoms were found to lie within 50 %, for most cases; however, for some low energies, differences could amount to a factor of 3. The effective dose per unit source intensity per area was found to decrease by a factor of 2-5, for increasing relaxation depths from 0 to 5 g/cm(2), above a source energy of 50 keV. It is also shown that implementation of the calculated coefficients into the computation of the tissue weighting factors and the adult reference computational phantoms of ICRP Publication 103 does not significantly influence the effective dose conversion coefficients of the environment. Consequently, the coefficients shown in this paper could be applied for the evaluation of effective doses, as defined according to both recommendations of ICRP Publications 103 and 60.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Organ doses from environmental exposures calculated using the ICRP Reference Male and Reference Female voxel phantoms

In its recent recommendations the ICRP adopted two voxel models of an adult male and an adult female to be used for the forthcoming update of organ dose conversion coefficients. These voxel models are representative of an average population, i.e. they resemble the ICRP reference anatomical data with respect to their external dimensions and their organ masses and were constructed for this purpos...

متن کامل

Absorbed dose rate conversion coefficients for reference terrestrial biota for external photon and internal exposures.

The paper describes dosimetric models that allow the estimation of average radiation exposures to terrestrial biota due to environmental sources in the soil as well as internal uniform distributions of radionuclides. Simple three-dimensional phantoms for 13 faunal reference organisms are specified. The calculation of absorbed dose per unit source strength for these targets is based on photon an...

متن کامل

Radioactivity of surface soils from Oyo state, South Western Nigeria

Background: The activity concentrations of some radionuclides in soil samples collected from 20 locations in 8 major towns in Oyo State, Southwestern Nigeria have been determined by gamma-ray spectrometry technique. Materials and Methods: The activity concentrations were determined using high-purity germanium (HPGe) detector (Canberra Industries Inc.). The outdoor absorbed dose rates in air at ...

متن کامل

Absorbed Internal Dose Conversion Coefficients for Domestic Reference Animals and Plant

Traditionally, radiation protection has focused on the radiation exposure of human beings. Recently, since the Rio Declaration emphasized the issue of sustainable development [1], the protection of the environment from the effects of ionizing radiations has become a key subject for all relevant international organizations in the field of radiation protection. There have been a number of interna...

متن کامل

Development of an Accommodation-Dependent Eye Model and Studying the Effects of Accommodation on Electron and Proton Dose Conversion Coefficients

Introduction International Commission on Radiological Protection (ICRP) has provided a comprehensive discussion on threshold dose for radiation-induced cataract in ICRP publication 116. Accordingly, various parts of the eye lens have different radio-sensitivities. Recently, some studies have been performed to develop a realistic eye model with the aim of providing accurate estimation of fluence...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 51  شماره 

صفحات  -

تاریخ انتشار 2012