Exploring uncertainty in the calibration of the molecular clock.
نویسندگان
چکیده
Calibration is a critical step in every molecular clock analysis but it has been the least considered. Bayesian approaches to divergence time estimation make it possible to incorporate the uncertainty in the degree to which fossil evidence approximates the true time of divergence. We explored the impact of different approaches in expressing this relationship, using arthropod phylogeny as an example for which we established novel calibrations. We demonstrate that the parameters distinguishing calibration densities have a major impact upon the prior and posterior of the divergence times, and it is critically important that users evaluate the joint prior distribution of divergence times used by their dating programmes. We illustrate a procedure for deriving calibration densities in Bayesian divergence dating through the use of soft maximum constraints.
منابع مشابه
Dating divergence of Polystigma and other Sordariomycetes
Studies on the evolutionary history of ascomycetes in terms of time scale will help to understand historical patterns that shape their biodiversity. Until now most of dating studies of ascomycetes have focused on major events in fungal evolution but not on divergence events within smaller groups of fungi e.g. within Sordariomycetes. We used molecular dating to estimate the time of separation of...
متن کاملUsing SWAT and SWAT-CUP for hydrological simulation and uncertainty analysis in arid and semi-arid watersheds (Case study: Zoshk Watershed, Shandiz, Iran)
The aims of this project was to assess the capability of SWAT model and SWAT-CUP software in hydrological simulation and to evaluate the uncertainty of SWAT model in estimating runoff in arid and semi-arid watersheds. Model calibration and uncertainty analysis were performed using the Sequential Uncertainty Fitting (SUFI2) algorithm. In the stage of calibration and validation of water flow, per...
متن کاملCaveats on the Use of Fossil Calibrations for Molecular Dating: A Reply to Parham and Irmis
In Parham and Irmis’s (2008) commentary on our article “Assessing Concordance of Fossil Calibration Points in Molecular Clock Studies: An Example Using Turtles” (Near et al. 2005), these authors address three areas of concern with respect to fossil calibration analyses in general and our article in particular: (1) absolute age estimates for fossil calibration points, including the accuracy of t...
متن کاملUncertainty Analysis in MRI-based Polymer Gel Dosimetry
Background: Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin I...
متن کاملتخمین
Temporal and spatial distribution of water components in watersheds, estimation of water quality, and uncertaintiesassociated with these estimations are important issues in freshwater studies. In this study, Soil and Water AssessmentTool (SWAT) model was used to estimate components of freshwater availability: blue water (surface runoff plus deepaquifer recharge), green water flow (actual evapot...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biology letters
دوره 8 1 شماره
صفحات -
تاریخ انتشار 2012