Appraisal of the DIERS method for calculating postural measurements: an observational study

نویسندگان

  • Brian Degenhardt
  • Zane Starks
  • Shalini Bhatia
  • Geoffroey-Allen Franklin
چکیده

BACKGROUND Surface topography is increasingly used with postural analysis. One system, DIERS formetric 4D, measures 40 defined spine shape parameters from a 6-s scan. Through system algorithms, a set of spine shape parameter values from 1 of 12 recorded images obtained during a scan becomes the DIERS-reported value (DRV) for postural assessment. The purpose of the current study was to compare DRV with a standard average value (SAV) calculated from all 12 images to determine which method is more appropriate for assessing postural change. METHODS One mannequin and 30 human participants were scanned over 5 days. Values from each image and the DRV for 40 defined spine shape parameters were exported, and mean DRV, mean SAV, mean DRV, and within-scan variance were calculated. Absolute difference and percent change between mean DRV and mean SAV were calculated for the mannequin and humans. Inter-method reliability was calculated for humans. Within-scan variance for each parameter was tested for significant variability. RESULTS For all spine shape parameters on the mannequin, absolute difference (< 0.6 mm, 0.1°, or 0.1%) and percent change (< 2.90%) between mean DRV and mean SAV for each parameter were small. Nine parameters on human participants had a large percent change (> 7%). Absolute difference between mean DRV and mean SAV for those nine parameters was small (≤ 0.87 mm or 0.61°). Absolute difference for all other parameters ranged from 0.02 to 6.98 mm for distance measurements, from 0.01 to 1.21° for angle measurements, and from 0.15 to 0.22% for percentage measurements. Inter-method reliability between DRV and SAV was excellent (0.94-1.00). For the mannequin, within-scan variance was small (< 1.62) for all parameters. For humans, within-scan variance ranged from 0.05 to 36.04 and was different from zero for all parameters (all P < 0.001). CONCLUSIONS The minimal variability observed in the mannequin suggested the DIERS formetric 4D instrument had high within-scan reliability. The DRV and SAV provided comparable spine shape parameter values. Because within-scan variability is not reported with the DRV, the clinical usefulness of current DRV values is limited. Establishing an estimate of variance with the SAV will allow clinicians to better identify a clinically meaningful change.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of changes in postural alignment on foot pressure and walking ability of stroke patients

[Purpose] The aims of this study were to determine (1) the significance of walking and foot pressure in stroke patients, and (2) the association between changes in postural alignment of stroke patients. [Subjects and Methods] Foot pressure and walking ability based on postural alignment were measured in 50 stroke patients. Trunk imbalance, trunk rotation, pelvic tilt, kyphosis, lordosis were me...

متن کامل

Postural Ergonomic Risk Assessment (Pera) in The Workers of the Automobile Parts Assembly Line: A New Observational Method for the Cube Model

Assembly lines are associated with health risk and musculoskeletal disorders, particularly in the upper limbs. The aim of this study was to analyze three risk factors of posture, duration and force by using the postural ergonomic risk assessment (PERA) method in the workers of the assembly unit of automobile parts. Material and Methods: This descriptive cross-sectional study was conducted in th...

متن کامل

Two Phase Flow Pressure Drop Calculation Using Homogeneous Equilibrium Model

Although two-phase flow is frequently encountered in various location of the process plants, there is no a general accepted and verified two-phase flow model that may be used to size lines for such conditions. An obvious example is condensate water return lines. The API method that used in this study is based on the homogeneous equilibrium flow assumption, that is, equal velocity and equal temp...

متن کامل

Which Postural Control and Functional Movement Screen Values Related to Change of Direction Runs?

Background. Instead of different measurements of physical performances such as postural control, strength, and flexibility, studies investigating many abilities such as the harmony between these abilities and body segments simultaneously with the test FMS results and different physical relationships were performed. Meaningful results and other relationships between COD, FMS, and PC have previou...

متن کامل

Analysis of the role of teachers performance appraisal in school effectiveness with mediating role of job enthusiasm, justice perception and organizational trust

رThe purpose of this study  was  to analyse the role of  teachers  performance  appraisal  in  school  effectiveness  with  mediating  role of  job enthusiasm, justice  perception and organizational  trust. . This  research  was  an  applied  research in terms of the  aim and  it was descriptive  correlational  of causal type  research in terms  of  method The statistical population were all s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017