Removal torque of osseointegrated mini-implants: an in vivo evaluation.

نویسندگان

  • Luca Giuseppe Favero
  • Andrea Pisoni
  • Corrado Paganelli
چکیده

The possibility of using osseointegrated implants for orthodontic anchorage is well known. When absolute orthodontic anchorage is needed, mini-implants can be inserted in the non-alveolar bone area (e.g. palatal process or retromolar areas of the mandible). However, what happens to these implants at the end of treatment can be a problem as neither trephine explantation nor simply leaving the subgingival part of the implant in the bone permanently are acceptable solutions. In this investigation, 16 Exacta small screw titanium implants (Exacta MS series conical profile, with a diameter of 3.3 mm and a length of 7.0 mm) were used as indirect orthodontic anchorage in 16 adult patients. The site of implant placement was established based on radiological investigations. There were eight palatal and eight retromolar implants inserted in seven males and nine females (mean age 30.3 years). On completion of treatment, the implants were unscrewed to the maximum limits of their removal torque values (RTVs) and the obtained data were analysed using a t-test. An in vitro study before the clinical trial was also undertaken to determine the maximum mechanical resistance of the unscrewing system. The clinical procedure and average RTV (67.91 +/- 12.47 N/cm) were considered compatible with safe, non-invasive removal of the implant followed by rapid anatomical reconstruction of the area involved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Titanium alloy mini-implants for orthodontic anchorage: immediate loading and metal ion release.

Removable osseointegrated titanium mini-implants were successfully used as anchorage devices in orthodontics. The early load is necessary to simplify the mini-implant methodology, but can lead to failure during osseointegration. The Ti-6Al-4V alloy was used instead of commercially pure Ti due to its superior strength. However, the corrosion resistance is low, allowing for metal ion release. The...

متن کامل

Stability of smooth and rough mini-implants: clinical and biomechanical evaluation - an in vivostudy

OBJECTIVE To compare in vivo orthodontic mini-implants (MI) of smooth (machined) and rough (acid etched) surfaces, assessing primary and secondary stability. METHODS Thirty-six (36) MI were inserted in the mandibles of six (6) dogs. Each animal received six (6) MI. In the right hemiarch, three (3) MI without surface treatment (smooth) were inserted, whereas in the left hemiarch, another three...

متن کامل

Torque Removal Evaluation of Screw in One-Piece and Two-Piece Abutments Tightened with a Handheld screwdriver

Introduction: Some clinicians use a handheld screw driver instead of a torque wrench to definitively tighten abutment screws. The aim of this study was to compare the removal torque of one-piece and two-piece abutments tightened with a handheld driver and a torque control ratchet. Methods: 40 ITI implants were placed in acrylic blocks and divided into 4 groups. In groups one and two, 10 ITI one...

متن کامل

Evaluation of Stability of Surface-Treated Mini-Implants in Diabetic Rabbits

Introduction. The purpose of this study was to investigate effects of surface treatment of mini-implants in diabetes-induced rabbits by comparing osseointegration around mini-implants. Methods. Twelve New Zealand white rabbits were divided into two groups (alloxan-induced diabetic group and control group). A total of 48 mini-implants were placed after four weeks of diabetic induction. 24 mini-i...

متن کامل

Rotational resistance of surface-treated mini-implants.

OBJECTIVE To test the hypothesis that there is no difference in the stability and resistance to rotational moments of early loaded sandblasted and acid-etched (SLA) mini-implants and those of machined-surface implants of the same size and shape. MATERIALS AND METHODS A randomized complete block design was used in 12 skeletally mature male beagle dogs. Ninety-six orthodontic mini-implants were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 29 5  شماره 

صفحات  -

تاریخ انتشار 2007