Three-dimensional relationship between high-order root-mean-square wavefront error, pupil diameter, and aging.
نویسندگان
چکیده
We report root-mean-square (RMS) wavefront error (WFE) for individual aberrations and cumulative high-order (HO) RMS WFE for the normal human eye as a function of age by decade and pupil diameter in 1 mm steps from 3 to 7 mm and determine the relationship among HO RMS WFE, mean age for each decade of life, and luminance for physiologic pupil diameters. Subjects included 146 healthy individuals from 20 to 80 years of age. Ocular aberration was measured on the preferred eye of each subject (for a total of 146 eyes through dilated pupils; computed for 3, 4, 5, 6, and 7 mm pupils; and described with a tenth-radial-order normalized Zernike expansion. We found that HO RMS WFE increases faster with increasing pupil diameter for any given age and pupil diameter than it does with increasing age alone. A planar function accounts for 99% of the variance in the 3-D space defined by mean log HO RMS WFE, mean age for each decade of life, and pupil diameter. When physiologic pupil diameters are used to estimate HO RMS WFE as a function of luminance and age, at low luminance (9 cd/m2) HO RMS WFE decreases with increasing age. This normative data set details (1) the 3-D relationship between HO RMS WFE and age for fixed pupil diameters and (2) the 3-D relationship among HO RMS WFE, age, and luminance for physiologic pupil diameters.
منابع مشابه
Fitting Zernike polynomials to ocular wavefront aberrations. Effect of the radial order on the fitting accuracy
METHODS: Ocular wavefront maps were obtained from 19 normal eyes using a ShackHartmann aberrometer. The tenth Zernike order fit was considered to be the real wavefront of the eyes. Different fittings from second to ninth Zernike orders were computed and compared with the tenth order. The ratio of the root mean square (RMS) error between the different fittings and the original wavefront was calc...
متن کاملUncorrected wavefront error and visual performance during RGP wear in keratoconus.
PURPOSE To examine the relationship between uncorrected residual wavefront error and visual performance (VP) in rigid gas permeable (RGP) contact lens-wearing keratoconic eyes. METHODS Seven eyes from six subjects (six moderate, one severe) were studied (mean +/- SD age: 42.71 +/- 11.38 years). Significant corneal scarring was an exclusion criterion. Measurements were taken with RGP lenses in...
متن کاملComparison of wavefront aberrations under cycloplegic, scotopic and photopic conditions using WaveScan.
PURPOSE To evaluate the differences of wavefront aberrations under cycloplegic, scotopic and photopic conditions. METHODS A total of 174 eyes of 105 patients were measured using the wavefront sensor (WaveScan® 3.62) under different pupil conditions: cycloplegic 8.58 ± 0.54 mm (6.4 mm - 9.5 mm), scotopic 7.53 ± 0.69 mm (5.7 mm - 9.1 mm) and photopic 6.08 ± 1.14 mm (4.1 mm - 8.8 mm). The pupil ...
متن کاملChange in visual acuity is highly correlated with change in six image quality metrics independent of wavefront error and/or pupil diameter.
It is well known that the wavefront error (WFE) of the eye varies from individual to individual with pupil diameter (PD) and age. Numerous studies have been proposed evaluating the relationship between visual acuity and WFE, but all these studies were performed with either a fixed or natural PD. It is still not clear if metrics of image quality correlate well with visual acuity independent of P...
متن کاملOcular anterior segment biometry and high-order wavefront aberrations during accommodation.
PURPOSE We investigated the relationships between the ocular anterior segment biometry and the ocular high-order aberrations (HOAs) during accommodation by combined ultralong scan depth optical coherence tomography (UL-OCT) and wavefront sensor. METHODS We enrolled 35 right eyes of young healthy subjects (21 women and 14 men; age, 25.6 ± 3.1 years; spherical equivalent refractive error, -0.41...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Optical Society of America. A, Optics, image science, and vision
دوره 24 3 شماره
صفحات -
تاریخ انتشار 2007