Determination of inorganic anions in natural water by microcolumn ion chromatography with on-column enrichment.

نویسندگان

  • Lee Wah Lim
  • Ji-Ye Jin
  • Toyohide Takeuchi
چکیده

An on-column enrichment method was developed for the rapid determination of inorganic anions in natural water. The system was assembled from a syringe pump, a six-port switching valve with a sample-enrichment loop, a separation column and a UV detector. The enrichment efficiency of the system was tested by using inorganic anions as samples. The limits of detection were between 0.6 and 7.7 microg/L. The system was applied to the determination of anions in river and pond-water samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of inorganic anions in environmental waters with a hydroxide-selective column.

US Environmental Protection Agency Method 300.0 specifies the use of an IonPac AS4A anion-exchange column with a carbonate-hydrogencarbonate eluent and suppressed conductivity detection for the determination of inorganic anions in environmental waters by ion chromatography. Hydroxide eluents have not typically been used for the routine analysis of common inorganic anions due to the lack of an a...

متن کامل

Determination of anions at trace levels in power plant water samples by ion chromatography with electrolytic eluent generation and suppression.

An ion chromatographic method was developed for the determination of nine inorganic and organic acid anions at sub- to low-microg/l levels in power plant water samples. In this method, samples were injected using a large-volume direct injection technique, the analyte anions were separated on a hydroxide-selective anion-exchange column using high-purity hydroxide eluents generated by an on-line ...

متن کامل

Cyclodextrin-aided determination of iodate and bromate in drinking water by microcolumn ion chromatography with precolumn enrichment.

A selective and simple method for the determination of iodate (IO3-) and bromate (BrO3-) by microcolumn ion chromatography (IC) is presented. In this study, IO3- and BrO3- were determined as IBr2- and tribromide (Br3-), respectively, via a postcolumn reaction with bromide (Br) under acidic conditions with the aid of alpha-cyclodextrin (alpha-CD) in microcolumn IC. IO3- and BrO3- were selectivel...

متن کامل

Recent progress and applications of ion-exclusion/ion-exchange chromatography for simultaneous determination of inorganic anions and cations.

One of the ultimate goals of ion chromatography is to determine both anions and cations found in samples with a single chromatographic run. In the present article, recent progress in ion-exclusion/ion-exchange chromatography for the simultaneous determinations of inorganic anions and cations are reviewed. Firstly, the principle and the control for the simultaneous separation and detection of ...

متن کامل

Simultaneous determination of Fe(III) and Fe(II) ions via complexation with salicylic acid and 1,10-phenanthroline in microcolumn ion chromatography.

Fe(III) and Fe(II) ions were separated and determined via in-column and post-column reactions with salicylic acid and 1,10-phenanthroline by microcolumn ion chromatography with UV-Vis detection. The separation could be achieved on a silica microcolumn using an aqueous ethanol solution of salicylic acid as eluent. The effluent from the column was then mixed with aqueous ethanol solution of 1,10-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 2003