Efficacy of air/water syringe tip sterilization.

نویسندگان

  • M Inger
  • V Bennani
  • M Farella
  • F Bennani
  • R D Cannon
چکیده

BACKGROUND Dental procedures involve contact between instruments and the patient's tissues, blood or saliva. This study evaluated the efficacy of the standardized sterilization of non-disposable air/water syringe tips and corrosion and contaminant build-up in these tips. METHODS The bacterial contamination of single-use and multiple-use non-disposable air/water syringe tips after routine use and sterilization was compared to that of single-use disposable tips by microbial culturing on PCA and blood agar plates. The effect of flushing the syringe tips prior to sterilization was also measured. The amount of corrosion in single-use and multiple-use non-disposable syringes was measured by SEM and EDS analyses. RESULTS Non-disposable syringe tips had significantly (p < 0.05) greater bacterial contamination than single-use disposable tips. There were no statistically different levels of contamination between flushed and non-flushed non-disposable syringes or between single-use and multiple-use non-disposable syringes. SEM and EDS analyses showed greater evidence of corrosion and contaminant build-up in multiple-use syringes compared to single-use non-disposable syringes. CONCLUSIONS Sterilization of non-disposable air/water syringes is not completely effective and rinsing, or the number of uses, does not affect the effectiveness of sterilization. There may be a lower risk of cross-infection from the use of disposable air/water syringe tips, instead of non-disposable ones.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sterilization of syringes by infra-red radiation.

more, syringes cannot be sterilized assembled or lubricated, and the syringe containers, whether multiple or single, must be so constructed that steam can freely penetrate to all surfaces of the syringe (Stewart, 1957; Darmady and Hughes, 1955). After sterilization a separate process is necessary to seal the containers before distribution to the user. Although syringes in their containers can b...

متن کامل

Accidental ingestion of an air-water syringe tip during routine dental treatment: a case report.

Accidental ingestion of instruments or their components is a possible complication of dental treatment. Although in many cases the foreign object can pass through the gastrointestinal tract without any need for surgical intervention to retrieve it, sometimes such incidents can be life-threatening. This paper reports a case of accidental ingestion of an air-water syringe tip during routine denta...

متن کامل

Sterilization of Hypodermic Syringe

Sir,?With reference to the query on p. 297 of your May issue, the method used by me for sterilizing syringes Js described below:? I carry a few " Soloid " examethylenetetrainine (B. W. & Co.) and a spoon in my injection outfit. The needle !s boiled in the spoon over the burning soloid which gives out a good heat. The boiling water is also drawn into the syringe several times. I have given a goo...

متن کامل

The Planning and Organization of Central Syringe Services

CENTRAL SYRINGE SERVICES. (Pp. 59. 3s. 6d.) London: Nuffield Provincial Hospitals Trust, 1957. THE sterilization of syringes by boiling is acknowledged to be uncertain and unsatisfactory, but it is still common practice in most hospitals. During the last few years an increasing number of hospitals have developed a central sterile syringe service. Most of the teething troubles have now been over...

متن کامل

بررسی اثر استریلیزاسیون خشک و مرطوب بر سایش لیگاچرکاترهای ارتودنتیک

Background and Aim: Orthodontic ligature cutting pliers are expensive. Methods of sterilization should be safe considering patients' health as well as lifetime of orthodontic pliers. The purpose of this study was to compare the wear of orthodontic ligature cutting pliers after sterilizing with dry heat or steam autoclave. Materials and Methods: In this experimental study, thirty ligature cuttin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Australian dental journal

دوره 59 1  شماره 

صفحات  -

تاریخ انتشار 2014