Screening of the spine in adolescents: inter- and intra-rater reliability and measurement error of commonly used clinical tests
نویسندگان
چکیده
BACKGROUND Evidence on the reliability of clinical tests used for the spinal screening of children and adolescents is currently lacking. The aim of this study was to determine the inter- and intra-rater reliability and measurement error of clinical tests commonly used when screening young spines. METHODS Two experienced chiropractors independently assessed 111 adolescents aged 12-14 years who were recruited from a primary school in Denmark. A standardised examination protocol was used to test inter-rater reliability including tests for scoliosis, hypermobility, general mobility, inter-segmental mobility and end range pain in the spine. Seventy-five of the 111 subjects were re-examined after one to four hours to test intra-rater reliability. Percentage agreement and Cohen's Kappa were calculated for binary variables, and interclass correlation (ICC) and Bland-Altman plots with Limits of Agreement (LoA) were calculated for continuous measures. RESULTS Inter-rater percentage agreement for binary data ranged from 59.5% to 100%. Kappa ranged from 0.06-1.00. Kappa ≥ 0.40 was seen for elbow, thumb, fifth finger and trunk/hip flexion hypermobility, pain response in inter-segmental mobility and end range pain in lumbar flexion and extension. For continuous data, ICCs ranged from 0.40-0.95. Only forward flexion as measured by finger-to-floor distance reached an acceptable ICC(≥ 0.75). Overall, results for intra-rater reliability were better than for inter-rater reliability but for both components, the LoA were quite wide compared with the range of assessments. CONCLUSION Some clinical tests showed good, and some tests poor, reliability when applied in a spinal screening of adolescents. The results could probably be improved by additional training and further test standardization. This is the first step in evaluating the value of these tests for the spinal screening of adolescents. Future research should determine the association between these tests and current and/or future neck and back pain.
منابع مشابه
The inter and intra rater reliability of the Netball Movement Screening Tool.
OBJECTIVES To establish the inter- and intra-rater reliability of the Netball Movement Screening Tool, for screening adolescent female netball players. DESIGN Inter- and intra-rater reliability study. METHODS Forty secondary school netball players were recruited to take part in the study. Twenty subjects were screened simultaneously and independently by two raters to ascertain inter-rater a...
متن کاملبررسی پایایی بین دو آزمونگر و پایایی یک آزمونگر تست بریف بست در ارزیابی تعادل بیماران مبتلا به سکته مغزی: گزارش کوتاه
Background: Impaired balance is one of the most common symptoms that occur after stroke. There are several tests for evaluating balance in neurological disorders. Brief-balance evaluation systems test (Brief-BESTest) is the short version of BESTest that assess the systems contributing to postural control. The purpose of this study was to investigate the inter- and intra-rater reliability of the...
متن کاملTest-retest, inter- and intra-rater reliability of the flexicurve for evaluation of the spine in children
INTRODUCTION The early evaluation of the spine in children is desirable because it is at this stage of development that the greatest changes in the body structures occur. OBJECTIVE To determine the test-retest, intra- and inter-rater reliability of the Flexicurve instrument for the evaluation of spinal curvatures in children. METHOD Forty children ranging from 5 to 15 years of age were eval...
متن کاملFunctional Movement Screen in Elite Boy Basketball Players: A Reliability Study
Purpose: To investigate the reliability of Functional Movement Screen (FMS) in basketball players. A few studies have compared the reliability of FMS between raters with different experience in athletes. The purpose of this study was to compare the FMS scoring between the beginners and expert raters using video records. Methods: This is a cross-sectional study. The study subjects compris...
متن کاملEvaluation of Spasticity Using the Ashworth Scale with Intermediate Scores (ASIS)
Objectives: The main purpose of this research was to study and contribute to an accurate test of spastic limb. The intra, inter rater reliability of the test was examined. Methods: The present study was carried out in two parts In the first part of the study, the modified Ashworth Scale with Intermediate Scores (ASIS) was studied. During the second part of the study the intra, inter rater re...
متن کامل