[A new method for determination of toluene-2,4-diamine and toluene-2,6-diamine in workplace air].
نویسندگان
چکیده
BACKGROUND Toluenediamines are harmful substances. Toluene-2,4-diamine has been assigned to Carcinogen 1B hazard class, pursuant to Regulation (European Community - EC) No. 1272/2008 of the European Parliament and of the Council, and toluene- 2,6-diamine to Mutagen 2 hazard class. The main routes of exposure to toluene-2,4-diamine and toluene-2,6-diamine are via the respiratory tract and the skin. Toluene-2,4-diamine and toluene-2,6-diamine occur in the work environment in Poland. The aim of this study was to develop and validate a method for the determination of toluene-2,4-diamine and toluene-2,6-diamine that allows the simultaneous determination of their concentrations in the workplace air by personal sampling. MATERIAL AND METHODS Determination of toluene-2,4-diamine and toluene-2,6-diamine derivatives in acetonitrile were carried out by means of liquid chromatography with a diode assay detector. The method involves passing amine-containing air through sulfuric acidtreated glass fiber filter, washing out the substance settled on the filter, using water and solution of sodium hydroxide, followed by the extraction with toluene, reaction with 3,5-dinitobenzoyl chloride, replacement of dissolvent with acetonitrile and analysis of obtained solution. RESULTS The method developed in this study enables the researcher to determine the content of toluene-2,4-diamine and toluene-2,6-diamine in the presence of other hazardous substances. In the specified measuring range (2.88-57.6 μg/ml) calibration curves are linear. Under the optimized conditions of determination, the limit of detection (LOD) values achieved: 51.36 ng/ml for toluene-2,4-diamine and 52.93 ng/ml for toluene-2,6-diamine. CONCLUSIONS This method makes it possible to determine the concentration of toluene-2,4-diamine and toluene-2,6-diamine in the workplace air within the specified measuring range of 0.004-0.08 mg/m3 (for air sample volume of 720 l). Med Pr 2017;68(4):497-505.
منابع مشابه
Elimination kinetics of diisocyanates after specific inhalative challenges in humans: mass spectrometry analysis, as a basis for biomonitoring strategies
BACKGROUND Isocyanates are some of the leading occupational causes of respiratory disorders, predominantly asthma. Adequate exposure monitoring may recognize risk factors and help to prevent the onset or aggravation of these aliments. Though, the biomonitoring appears to be most suitable for exposure assessment, the sampling time is critical, however. In order to settle the optimal time point f...
متن کاملStatistical Comparison of Carcinogenic Effects and Dose-Response Relationships in Rats and Mice for 2,4-Toluene Diamine to those Ascribed to Toluene Diisocyanate
The U.S. National Toxicology Program (NTP) conducted 2-year bioassays of commercial grade toluene diisocyanate (TDI) (80% 2,4-TDI and 20% 2,6-TDI) and 2,4-toluene diamine (TDA) and concluded that both were carcinogenic in rodents. In the TDI study, there was an unproven but likely formation of TDA either because of flawed test-substance handling and storage conditions and/or the atypical exposu...
متن کاملIdentification and Analysis of the Migration of Primary Aromatic Amines from Flexible Food Packaging by High-performance Liquid Chromatography (HPLC)
Background and Objectives: Primary Aromatic Amines (PAAs) are contaminants that can migrate from food flexible packaging. The main origin of these compounds is polyurethane adhesives used in the laminating process of multilayer films. Residual aromatic di-isocyanates of the reaction of adhesive polymerization migrate into the food, and are hydrolyzed to PAAs by the moisture of food. 2,4- and 2,...
متن کاملBiological monitoring of occupational exposure to toluene diisocyanate.
The study validated the use of urinary toluene diamine (TDA) in postshift samples as an indicator of preceding 8-h exposure to toluene diisocyanate (TDI). Nine workers exposed in TDI-based polyurethane foam production were studied. Their exposure levels varied in 8-h time-averaged samples from 9.5 to 94 micrograms/m3. The urinary TDA concentrations varied from 6.5 to 31.7 micrograms/g creatinin...
متن کاملAn Improved Impregnated-Filter Method for Measuring Low-Level Concentrations of Toluene Diisocyanates in Air
An improved method was developed and validated for measuring low-level concentrations of toluene diisocyanates (TDls) in air. The method is based on OSHA Method 42 for industrial applications. Airborne TDls were trapped on a 25-mm glass-fiber filter impregnated with 50 pg of 1-(2pyridy1)piperazine. A filter holder for was constructed to minimize contamination and losses of the analytes. The der...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medycyna pracy
دوره 68 4 شماره
صفحات -
تاریخ انتشار 2017