Gas-phase ion association provides increased selectivity and sensitivity for measuring perchlorate by mass spectrometry.
نویسندگان
چکیده
Perchlorate (ClO4-) competitively inhibits the uptake of iodide by the thyroid gland. Trace quantities of perchlorate are being increasingly detected in food and environmental samples. There is great concern that perchlorate contamination may be far more widespread than believed until now. Increasingly sensitive and unambiguous methods are needed for measuring perchlorate. We report here an ion chromatography-ion association-electrospray ionization-mass spectrometry (IC/IA-ESI-MS) method of substantially greater selectivity and sensitivity than other available single-stage MS approaches. A long chain dipositive cationic agent (D2+) is added postcolumn in low concentration. This ion associates with perchlorate, even in the gas phase. Perchlorate is, thus, detected as DClO4+ in the positive ion mode at an m/z value between 300 and 400 (depending on the choice of D2+). This results in much better S/N and selectivity, as compared to detecting 35ClO4- at m/z 99, where H34SO4- also responds. We show results for various dicationic agents which vary in their selectivity and affinity for ClO4-, typically being at least 1 order of magnitude more selective for ClO4- over HSO4-. For a 100-microL injected standard, limits of detection (LOD, S/N = 3) are as good as 25 ng/L on a single quadrupole mass spectrometer. Calibration for concentrations up to 100 microg/L displays an r2 value of > or =0.9993. We show applicability to various real samples. A number of the studied reagents are suitable for such applications.
منابع مشابه
Determination of Ultratrace Level Perchlorate in Liquid and Powdered Baby Formula
Perchlorate is a widespread contaminant in the United States.1 Research has demonstrated its presence in various media, including water, soil, various foods, and also human biological fluids, such as urine and breast milk.2-6 Perchlorate causes an adverse health effect by competitively inhibiting iodide uptake by the thyroid gland because it exhibits a much higher selectivity factor than iodide...
متن کاملMicroscale extraction of perchlorate in drinking water with low level detection by electrospray-mass spectrometry.
Improper treatment and disposal of perchlorate can be an environmental hazard in regions where solid rocket motors are used, tested, or stored. The solubility and mobility of perchlorate lends itself to ground water contamination, and some of these sources are used for drinking water. Perchlorate in drinking water has been determined at sub-mug l(-1) levels by extraction of the ion-pair formed ...
متن کاملDetermination of perchlorate at trace levels in drinking water by ion-pair extraction with electrospray ionization mass spectrometry.
Perchlorate has been added to the U.S. Environmental Protection Agency's Drinking Water Contaminant Candidate List (CCL). The present work describes the analysis of perchlorate in water by liquid-liquid extraction followed by flow injection electrospray mass spectrometry (ESI/MS). Cationic surfactants, mostly alkyltrimethyl-ammonium salts, are used to ion-pair aqueous perchlorate, forming extra...
متن کاملProduction and collision-induced dissociation of gas-phase, water- and alcohol-coordinated uranyl complexes containing halide or perchlorate anions.
Electrospray ionization was used to generate mono-positive gas-phase complexes of the general formula [UO2A(S)n]+ where A = OH, Cl, Br, I or ClO4, S = H2O, CH3OH or CH3CH2OH, and n = 1-3. The multiple-stage dissociation pathways of the complexes were then studied using ion-trap mass spectrometry. For H2O-coordinated cations, the dissociation reactions observed included the elimination of H2O li...
متن کاملThe Analysis of Perchlorate by Ion Chromatography/Mass Spectrometry Application
A method for the determination of perchlorate anion at sub ppb levels using ion chromatography/mass spectrometry (IC/MS) is described. The IC/MS method follows EPA Method 314 methodology originally developed for IC with conductivity detection at the single ppb range [1]. The IC/MS method is not affected by the addition of the interference matrix described in Method 314 on perchlorate recoveries...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 77 15 شماره
صفحات -
تاریخ انتشار 2005