Three-dimensional echo-guided beating heart surgery without cardiopulmonary bypass: atrial septal defect closure in a swine model.

نویسندگان

  • Yoshihiro Suematsu
  • Joseph F Martinez
  • Benjamin K Wolf
  • Gerald R Marx
  • Jeffrey A Stoll
  • Pierre E DuPont
  • Robert D Howe
  • John K Triedman
  • Pedro J del Nido
چکیده

OBJECTIVE In this study, we tested 3 techniques of atrial septal defect closure under real-time 3-dimensional echocardiography guidance in a swine model. METHODS The operations were conducted under the sole guidance of a modified real-time 3-dimensional echocardiography guidance system with a x4 matrix transducer (Sonos 7500, Philips Medical Systems, Andover, Mass). Eighteen swine were anesthetized, and after median sternotomy, the echo probe was applied directly to the surface of the right atrium. To create an atrial septal defect, balloon atrial septostomy and atrial septal defect enlargement were performed. Subsequently, 3 different techniques of atrial septal defect closure were attempted: group I, direct suture closure; group II, closure of the atrial septal defect using the Amplatzer device (AGA Medical Corp, Golden Valley, Minn); and group III, patch closure of the atrial septal defect (n = 6 each). RESULTS Real-time 3-dimensional echocardiography guidance provided sufficient spatial resolution and a satisfactory frame rate to provide a "virtual surgeon's view" of the relevant anatomy during the entire procedure. All atrial septal defects were enlarged, and the mean final size was 8.5 +/- 1.8 mm. Atrial septal defect closure was successfully accomplished with all the 3 surgical techniques examined. In groups I and III, the needles (1-3 sutures) and staples (6-12 staples) penetrated the tissue and patch material consistently, whereas in group III, the Amplatzer atrial septal defect device was easily deployed. There was no incident device/staple embolization or air introduction. Neither intraoperative 2-dimensional color Doppler echocardiography nor postmortem macro-evaluation revealed any residual shunts. CONCLUSIONS Beating heart atrial septal defect closure under real-time 3-dimensional echocardiographic guidance is feasible and, unlike catheter-based devices, applicable for any type of secundum atrial septal defect.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional echo-guided suture of atrial septal defect with Maniceps in an experimental model.

Toward the establishment of suture closure procedures for atrial septal defect or patent foramen ovale under guidance of three-dimensional (3D) echocardiography but without use of cardiopulmonary bypass (off-pump surgery), an experimental study was conducted using a laparoscopic suture instrument, Maniceps. First, the panel setting of the 3D echo system which was optimal for precisely visualizi...

متن کامل

Three-dimensional echocardiography-guided beating-heart surgery without cardiopulmonary bypass: a feasibility study.

BACKGROUND There is no current acceptable approach for intracardiac beating-heart interventions. We have adapted real-time 3-dimensional echocardiography with specialized instrumentation to facilitate beating-heart repair of atrial septal defects and mitral valve plasty to investigate the feasibility of real-time 3-dimensional echocardiography-guided cardiac surgery. METHODS In experiment I a...

متن کامل

Beating atrial septal defect closure monitored by epicardial real-time three-dimensional echocardiography without cardiopulmonary bypass.

BACKGROUND We assessed the feasibility of beating atrial septal defect (ASD) closure monitored by real-time 3D echocardiography (RT3DE). METHODS AND RESULTS RT3DE was developed with prototype ultrasound equipment consisting of a high-speed 3D rendering unit with a frame rate of 5 to 10 frames/s. We also developed a prototype semiautomatic suture device and suture cutting system. In the experi...

متن کامل

Robotic-assisted endoscopic atrial septal defect closure: analysis of 115 cases in a single center.

OBJECTIVE To summarize the experience with the application of robotic technique in totally endoscopic atrial septal defect closure in a single center. METHODS Between January 2007 and September 2011, 115 patients with the diagnosis of secundum type atrial septal defects underwent robotic atrial septal defect repair with the assistance of da Vinci surgical system. The patients had a median age...

متن کامل

Totally Endoscopic Cardiac Surgery for Atrial Septal Defect Repair on Beating Heart Without Robotic Assistance in 25 Patients

OBJECTIVE The aim of the study was to investigate the effectivity and safety of totally endoscopic cardiac surgery without robotic assistance for atrial septal defect (ASD) closure on beating hearts. METHODS Twenty-five patients (adults/children: 15/10) underwent ASD closure using nonrobotically assisted totally endoscopic approach on beating heart. Three 5-mm trocars and one 12-mm trocar wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of thoracic and cardiovascular surgery

دوره 130 5  شماره 

صفحات  -

تاریخ انتشار 2005