Sampling of high amounts of bioaerosols using a high-volume electrostatic field sampler.
نویسندگان
چکیده
For studies of the biological effects of bioaerosols, large samples are necessary. To be able to sample enough material and to cover the variations in aerosol content during and between working days, a long sampling time is necessary. Recently, a high-volume transportable electrostatic field sampler for collection of fine particles has been described. The aim of this study was to investigate whether this sampler can be used for collection of high amounts of authentic bioaerosols that can subsequently be used for biological analysis. The investigation was carried out at a biofuel plant in a straw storage room and in a boiler room over two seasons. The sampled dust was quantified in terms of mass and characterized regarding microbial components and compared with dust sampled by Gravikon and GSP samplers. For the electrostatic field sampler, a prefilter was used to remove large objects. The prefilter was characterized for particle penetration and this testing indicated that the prefilter did not remove particles up to 10 mum, and therefore respirable dust was sampled by the electrostatic field sampler. Using the electrostatic field sampler in the straw storage and in the boiler room, 330 and 315 mg dust (net recovery of the lyophilized dust) was sampled during a period of 7 days, respectively. The sampling rates of the electrostatic field samplers were between 1.34 and 1.96 mg dust per hour, the value for the Gravikon was between 0.083 and 0.108 mg dust per hour and the values for the GSP samplers were between 0.0031 and 0.032 mg dust per hour. The standard deviations of replica samplings and the following microbial analysis using the electrostatic field sampler and GSP samplers were at the same levels. The exposure to dust in the straw storage was 7.7 mg m(-3) when measured by the electrostatic field sampler and 11.8 mg m(-3) when measured by the GSP inhalable dust sampler. The quantity (amount per mg dust) of total fungi, Aspergillus fumigatus, total bacteria, endotoxin and mesophilic actinomycetes sampled by the electrostatic field samplers and the Gravikon samplers varied within the same season by a factor smaller than four. The quantities of some microbial components were higher in the dust collected with all samplers in March than in August. In conclusion, by using the electrostatic field sampler, it was possible to sample replicas of large authentic aerosol samples that can be used, e.g. biological analysis.
منابع مشابه
Field Evaluation of Personal Sampling Methods for Multiple Bioaerosols
Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient c...
متن کاملPerformance Characteristics of Personal Samplers in Still and Moving Air
Personal samplers or in general blunt body samplers are widely used in occupational hygiene for collecting air contaminants in the work environments. This work is part of an ongoing research into the performance evaluation of personal samplers, particularly in terms of their aerodynamic properties. Velocity profiles have been measured around and within typical cylindrical sampling devices, ...
متن کاملFast Monitoring of Indoor Bioaerosol Concentrations with ATP Bioluminescence Assay Using an Electrostatic Rod-Type Sampler
A culture-based colony counting method is the most widely used analytical technique for monitoring bioaerosols in both indoor and outdoor environments. However, this method requires several days for colony formation. In this study, our goal was fast monitoring (Sampling: 3 min, Detection: < 1 min) of indoor bioaerosol concentrations with ATP bioluminescence assay using a bioaerosol sampler. For...
متن کاملDevelopment of a new sampling medium for bioaerosols.
OBJECTIVE To develop a new sampling medium for detecting of bioaerosols. METHODS The sampling media were tested by using Escherichia coli, Staphylococcus aureus and Serratia marcescens under static and active conditions, preliminary applications were performed using AGI-10 and high volume sampler. RESULTS The average recovery rates were raised to 24.7%, 58.2%, 40.5%, 44.1%, 20.5%, and 15.4%...
متن کاملPii: S0003-4878(99)00042-3
Existing samplers for the collection of bioaerosols have been designed with the aim of maintaining biological stability of the collected material, and in general do not select particles in accordance with international conventions for aerosol sampling. Many have uncharacterised sampling eciencies and few are designed as personal samplers. If standard personal dust samplers are used for bioaero...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Annals of occupational hygiene
دوره 52 3 شماره
صفحات -
تاریخ انتشار 2008