Evaluation of the ShuntCheck noninvasive thermal technique for shunt flow detection in hydrocephalic patients.
نویسندگان
چکیده
BACKGROUND ShuntCheck (Neuro Diagnostic Devices, Inc., Trevose, Pennsylvania) is a new device designed to detect cerebrospinal fluid (CSF) flow in a shunt by sensing skin temperature downstream from a region of CSF cooled by an ice cube. OBJECTIVE To understand its accuracy and utility, we evaluated the use of this device during routine office visits as well as during workup for suspected shunt malfunction. METHODS One hundred shunted patients were tested, including 48 evaluated during possible shunt malfunction, of whom 24 went on to surgical exploration. Digitally recorded data were blindly analyzed and compared with surgical findings and clinical follow-up. RESULTS Findings in the 20 malfunctioning shunts with unambiguous flow or absence of flow at surgery were strongly correlated with ShuntCheck results (sensitivity and specificity to flow of 80% and 100%, respectively, P = .0007, Fisher's exact test, measure of agreement κ = 0.8). However, the thermal determination did not distinguish patients in the suspected malfunction group who received surgery from those who were discharged without surgery (P = .248 by Fisher's exact test, κ = 0.20). Half of the patients seen in routine office visits did not have detectable flow, although none required shunt revision on clinical grounds. Intermittent flow was specifically demonstrated in one subject who had multiple flow determinations. CONCLUSION Operative findings show that the technique is sensitive and specific for detecting flow, but failure to detect flow does not statistically predict the need for surgery. A better understanding of the normal dynamics of flow in individual patients, which this device may yield, will be necessary before the true clinical utility of non-invasive flow measurement can be assessed.
منابع مشابه
Radionuclide shuntography in a hydrocephalic patient
Radionuclide shuntography is a safe and simple method to determine shunt patency and analyze changes in CSF (Cerebro-Spinal-Fluid) flow. We present a case of complicated CSF shunt, in which radioisotopic scan correctly identified disconnection of the shunt tubing system localizing the site of extravasation accurately. The findings were confirmed by surgery performed for correction of the ...
متن کاملDirect Visualization and Quantitation of CSF flow in Shunts
Introduction Diversion of excessive cerebral spinal fluid (CSF) from hydrocephalic brains by shunting is, in many cases, a life saving procedure. The down side of shunting is high failure rate (40% in the first year, and about 10% annually thereafter). Consequently, about 43% of the estimated 40,000 shunting procedures performed annually in the US alone are for shunt replacement. A study of imp...
متن کاملMetrizamide Shuntography for Evaluation of Shunt Malfunction
Ventricular shunts were 'evaluted by a shuntographic technique using metrizamide for the contrast material and delayed spot films and computed tomography (CT) to evaluate shunt function. Thirty hydrocephalic patients were studied who had clinical presentations of shunt malfunction, Fifty-two shuntograms were obtained; most demonstrated the cause of shunt malfunction. No contrast-related complic...
متن کاملNoninvasive Doppler echocardiographic evaluation of shunt flow dynamics of the ductus arteriosus.
The pulsed Doppler technique was used to record the flow velocity patterns in the ductus arteriosus and the pulmonary artery in 26 patients with either isolated or complicated patent ductus arteriosus (PDA). In all patients, abnormal Doppler signals indicating left-to-right (L-R) or right-to-left shunt flow or both could be obtained at the site of the ductus arteriosus. These Doppler flow patte...
متن کاملContrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates
Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...