Sequelae of large-head metal-on-metal hip arthroplasties
نویسندگان
چکیده
Large-head metal-on-metal (MoM) bearings were re-popularised in the late 1990s with the introduction of modern hip resurfacing (HR), followed closely by large metal head total hip arthroplasty (THA). A worldwide increase in the use of MoM hip arthroplasty subsequently saw a sharp decline, due to serious complications.MoM was rapidly adopted in the early 2000s until medical device alerts were issued by government regulatory agencies and national and international organisations, leading to post-marketing surveillance and discontinuation of these implants.Guidelines for MoM hip implant follow-up differ considerably between regulatory authorities worldwide; this can in part be attributed to missing or conflicting evidence.The authors consider that the use of large-head MoM THA should be discontinued. MoM HR should be approached with caution and, when considered, should be used only in patients who meet all of the recommended selection criteria, which limits its indications considerably.The phased introduction of new prostheses should be mandatory in future. Close monitoring of outcomes and long-term follow-up is also necessary for the introduction of new prostheses. Cite this article: van Lingen CP, Zagra LM, Ettema HB, Verheyen CC. Sequelae of large-head metal-on-metal hip arthroplasties: current status and future prospects. EFORT Open Rev 2016;1:345-353. DOI: 10.1302/2058-5241.1.160014.
منابع مشابه
Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial
BACKGROUND Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentr...
متن کاملDistributed analysis of hip implants using six national and regional registries: comparing metal-on-metal with metal-on-highly cross-linked polyethylene bearings in cementless total hip arthroplasty in young patients.
BACKGROUND The regulation of medical devices has attracted controversy recently because of problems related to metal-on-metal hip implants. There is growing evidence that metal-on-metal implants fail early and cause local and systemic complications. However, the failure associated with metal-on-metal head size is not consistently documented and needs to be communicated to patients and surgeons....
متن کاملMetal-on-metal total hip arthroplasty: known and unknown side effects.
The indications for hip replacement, especially in young patients with end-stage degenerative arthritis of the hip, have increased during the past 20 years. Because of the accelerated risk of polyethylene wear and subsequent prosthetic loosening due to osteolysis, new interest has focused on the metal-on-metal articulation couple. Failures of first-generation metal-on-metal total hip arthroplas...
متن کاملSilent soft tissue pathology is common with a modern metal-on-metal hip arthroplasty
BACKGROUND AND PURPOSE Adverse reactions to metal debris have been reported to be a cause of pain in metal-on-metal hip arthroplasty. We assessed the incidence of both symptomatic and asymptomatic adverse reactions in a consecutive series of patients with a modern large-head metal-on-metal hip arthroplasty. METHODS We studied the early clinical results and results of routine metal artifact-re...
متن کاملA retrieval analysis of explanted Durom metal-on-metal hip arthroplasties.
Given the recent reports of high failure rates, an improved understanding of the mechanism of failure of large diameter metal-on-metal hip arthroplasties is essential. We present clinical data and tribological analysis of a consecutive series of 74 failed large diameter metal-on-metal hips, comparing the Durom (Zimmer) with the Birmingham hip resurfacing (BHR) (Smith and Nephew). We retrospecti...
متن کامل