Color evaluation of a dielectric mirror coating using porcine tissue and prosthetic gingival material: a comparison of two models.

نویسندگان

  • Christina Martina Pecnik
  • Daniel Muff
  • Ralph Spolenak
  • Irena Sailer
چکیده

AIM The aim of this study was to firstly evaluate the esthetics of a dielectric multilayer coating on titanium below porcine tissue (in vitro porcine model). Secondly, a polymer model was used to investigate the same samples to compare the models to each other and discuss their validity for optical assessment of esthetic coatings for implant applications. MATERIALS & METHODS A dielectric mirror coating was deposited on titanium substrates (Ti- Bragg) and tested below porcine tissue and polymer platelets of three test thicknesses (1 mm, 2 mm and 3 mm). Titanium without coating (Ti) was used as a negative control. Furthermore, the substrates were subjected to three different surface treatments (polished, machined and sand-blasted). The color difference values ΔL, Δa, Δb and ΔE were calculated for each sample. In total, six samples were tested in both models. Statistical analysis of the data (one sample Wilcoxon test, Kruskal-Wallis with Bonferroni-Holm corrected Mann-Whitney post hoc tests for multiple testing) was conducted for each sample in both evaluation methods. RESULTS In the in vitro porcine model, sand-blasted Ti-Bragg and Ti samples showed ΔE values significantly above the threshold value of 3.70, indicating a dark appearance of the 1 mm thick covering tissue. As the test thickness increased, polished and machined Ti-Bragg samples were significantly invisible (ΔE < 3.70 with P < 0.05). Excessive brightening effects from Ti-Bragg samples were not observed from the in vitro porcine model, but below polymer platelets the samples exhibited significantly high ΔL values, which also resulted in a significant and visible color change (ΔE >> 3.70 with P < 0.05). CONCLUSION Ti-Bragg was suggested to be an appropriate coating system for dental implants to improve the soft tissue esthetics. The design of this coating system can be adjusted by varying different parameters to satisfy the requirements of an esthetic coating. The polymer model is valid for test thicknesses of 2 and 3 mm, however, one might have to increase the thickness to 1.5 mm or alter the composition of the resin for 1 mm thick platelets to increase the opacity and therefore adapt to the soft tissue situation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dielectric Strontium Zirconate Sprayed by a Plasma Torch

Amultifunctional material, strontium zirconate, SrZrO3, studied in literatures as a dielectric ceramics, thermal barrier coating, proton-conductor, and luminescent material was sprayed by a water-stabilized plasma torch WSP 500. Stainless steel and plain carbon steel were used as substrates. Coatings with thickness of 1 to 2 mm were produced, whereas the substrates were preheated over 450 °C. T...

متن کامل

Cilnical comparison between free gingival graft with citric acid) subepithelial connective tissue graft) ‌in denuded roots coverage

Cilnical comparison between free gingival graft with citric acid) subepithelial connective tissue graft) ‌in denuded roots coverage Dr. A. Lafzi* - Dr. Gh. Gholami**- Dr. N. Abolfzali*** * - Associate professor of periodontics Dept.- Faculty of Dentistry- Tabriz University of Medical Sciences. ** - Associate professor of periodontics Dept.- Faculty of Dentistry- Shaheed Beheshti University of M...

متن کامل

Evaluation of anticorrosion behavior of automotive electrocoating primers by the AC-DC-AC accelerated test method

A protective coating has been applied onto the phosphated panels using cathodic electrocoating in two different dry film thickness namely 8µm and 20µm. The corrosion resistance of cathodic electrocoatings has been studied using AC/DC/AC method. Twelve cycles of AC/DC/AC test were carried out on each sample which the DC voltage of the first 6 cycles were -4 V VS. Ag/AgCl @ 20 minutes followed by...

متن کامل

Assessment of Color Changes in Vita 3D-Master Shade Guide after Sterilization and Disinfection

Purpose:Dental shade guides are commonly used for color determination and should be disinfected and sterilized. The purpose of this study was to evaluate the color change of Vita 3D Master shade tabs after disinfection and sterilization. Material and methods:Overall, 98 samples (shade tabs) were randomly selected from 14 new, unused Vita 3D sets, including the following shades: 2M1, 3L1.5, 3M1,...

متن کامل

Multilayer dielectric narrow band mangin mirror

The design of multilayer stack of dielectric films for narrow band mirror is developed using thin film coating software. The proposed design is materialized by employing thin film coating (PVD) method and reflectance in narrow band spectrum range is achieved. Thickness of high and low refractive index material is taken precisely up to nanometer level. The curved coated substrate is cemented wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical oral implants research

دوره 27 2  شماره 

صفحات  -

تاریخ انتشار 2016