Agreement between gonioscopy and ultrasound biomicroscopy in detecting iridotrabecular apposition.

نویسندگان

  • Yaniv Barkana
  • Syril K Dorairaj
  • Yariv Gerber
  • Jeffrey M Liebmann
  • Robert Ritch
چکیده

OBJECTIVE To assess the agreement between findings obtained at dark-room gonioscopy and ultrasound biomicroscopy (UBM) in the diagnosis of iridotrabecular apposition in light and dark conditions. METHODS We enrolled patients with appositional angle closure at dark-room gonioscopy performed using a 1-mm slitlamp beam that did not cross the pupil. Ultrasound biomicroscopic images were acquired in normal room light and subsequently with all room lights off. Images were evaluated for the presence or absence of iris-cornea contact. The angle opening distance at 500 microm was calculated. RESULTS Iridotrabecular apposition in at least 1 angle quadrant was demonstrated in all 18 eyes at dark-room gonioscopy, 17 eyes (94%) at dark-room UBM, and only 10 eyes (56%) at UBM in room light. Of 18 superior angles that were appositionally closed at dark-room gonioscopy, apposition was demonstrated on UBM images in 16 (89%) in a dark room but only 6 (33%) in room light. Angle opening distance was less during dark-room gonioscopy in all but the nasal quadrant. CONCLUSION We found high agreement between gonioscopy and UBM when both are performed in a completely dark room. Our findings support the recommendation that, in routine clinical practice, gonioscopy be performed in a dark room to avoid misdiagnosis of treatable iridotrabecular apposition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Argon laser peripheral iridoplasty for plateau iris associated with iridociliary cysts: a case report

INTRODUCTION Plateau iris is recognised as an important cause of primary angle closure glaucoma. The management of this condition generally comprises laser peripheral iridotomy and iridoplasty, to remove any component of relative pupillary block and to widen the iridotrabecular drainage angle respectively. However, plateau iris may be associated with multiple iris cysts at the iridociliary junc...

متن کامل

Iridotrabecular contact observed using anterior segment three-dimensional OCT in eyes with a shallow peripheral anterior chamber.

PURPOSE To evaluate the prevalence and range of iridotrabecular contact (ITC) in eyes with a shallow peripheral anterior chamber (AC) by using anterior segment swept-source optical coherence tomography (AS-SS-OCT) and to compare the results with those obtained with ultrasound biomicroscopy (UBM) and gonioscopy. METHODS Forty-three shallow peripheral AC eyes in 43 consecutive patients underwen...

متن کامل

Ciliary Body Tuberculosis Presenting with Attacks of Acute Intraocular Pressure Rise

Purpose: To report a rare presentation of ophthalmic tuberculosis. Case Report: A 19-year-old man was referred to the glaucoma clinic due to multiple attacks of increased intraocular pressure (IOP) in his right eye. IOP of the right eye was 50 mmHg, and glaucomatous damage of the optic nerve was present. In gonioscopy, an oval-black lesion was present in the ciliary body band on the temporal si...

متن کامل

2335 Evaluation of anterior chamber angle: Gonioscopy, ultrasound biomicroscopy and scheimpflug photography

m In addition to gonioscopy ultmsound biomicmscopy and Scheimpflug photography can be used to measure the imterior chamber angle width. The same subjects were measured with all three diagnostic tools and then the values were compared. v The anterior chamber angle width was measured in eight meridians in bath eyes of 20 volunteers without any history of ophthalmological problems. Gonioswpy was p...

متن کامل

Direct cyclopexy surgery for post-traumatic cyclodialysis with persistent hypotony: ultrasound biomicroscopic evaluation.

Cyclodialysis is a relatively rare condition usually caused by ocular injury; however, it can also be caused iatrogenically during intraocular surgery. Hypotony maculopathy is the most important complication and the primary reason for visual loss. Clinical diagnosis using gonioscopy may be difficult, and ultrasound biomicroscopy (UBM) can be an alternative. There are different kinds of treatmen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 125 10  شماره 

صفحات  -

تاریخ انتشار 2007