The Comparison of Environmental Effects on Michelson and Fabry-Perot Interferometers Utilized for the Displacement Measurement
نویسندگان
چکیده
The optical structure of general commercial interferometers, e.g., the Michelson interferometers, is based on a non-common optical path. Such interferometers suffer from environmental effects because of the different phase changes induced in different optical paths and consequently the measurement precision will be significantly influenced by tiny variations of the environmental conditions. Fabry-Perot interferometers, which feature common optical paths, are insensitive to environmental disturbances. That would be advantageous for precision displacement measurements under ordinary environmental conditions. To verify and analyze this influence, displacement measurements with the two types of interferometers, i.e., a self-fabricated Fabry-Perot interferometer and a commercial Michelson interferometer, have been performed and compared under various environmental disturbance scenarios. Under several test conditions, the self-fabricated Fabry-Perot interferometer was obviously less sensitive to environmental disturbances than a commercial Michelson interferometer. Experimental results have shown that induced errors from environmental disturbances in a Fabry-Perot interferometer are one fifth of those in a Michelson interferometer. This has proved that an interferometer with the common optical path structure will be much more independent of environmental disturbances than those with a non-common optical path structure. It would be beneficial for the solution of interferometers utilized for precision displacement measurements in ordinary measurement environments.
منابع مشابه
A novel algorithm for the signal interpolation of the displacement measurement based on a Fabry-Perot interferometer
Current commercial interferometers reveal excellent measurement performances, because of its major advantage which enables the displacement measurement with the characterization of the high resolution under the large measuring range. FabryPerot interferometer is a compact interferometer with the structure of common optical path. In comparison with the ordinary commercial laser interferometers h...
متن کاملNovel Optical Design of Folded Fabry-perot Displacement Measurement Interferometer
Due to its high resolution and the large measuring range, laser interferometer has been applied widely to the precision industrial measurement and calibration. Fabry-Perot interferometry was often used for the microdisplacement, because of its common optical path structure being insensitive to the environmental disturbances. In the past researches, some kinds of modified Fabry-Perot interferome...
متن کاملAll-reflective Michelson, Sagnac, and Fabry-Perot interferometers based on grating beam splitters.
All-reflective Michelson, Sagnac, and Fabry-Perot interferometers based on grating beam splitters are experimentally demonstrated at a wavelength of 1064 nm. A 1200-groove/mm grating diffracting 0 and -1 orders with an efficiency of 48.2% for each order was used as a near-50/50 beam splitter. The all-reflective Sagnac and Michelson interferometers were formed by reintroducing both of the diffra...
متن کاملChronology of Fabry-Perot Interferometer Fiber-Optic Sensors and Their Applications: A Review
Optical fibers have been involved in the area of sensing applications for more than four decades. Moreover, interferometric optical fiber sensors have attracted broad interest for their prospective applications in sensing temperature, refractive index, strain measurement, pressure, acoustic wave, vibration, magnetic field, and voltage. During this time, numerous types of interferometers have be...
متن کاملReduction of semiconductor laser diode phase and amplitude noise in interferometric fiber optic sensors.
An optical configuration employing two conventional Michelson interferometers and a fiber Fabry-Perot interferometer connected in parallel is used to demonstrate the principle of common mode rejection of both the amplitude and frequency noise of a semiconductor laser. Common mode noise rejection is maximized when the outputs of the two interferometers with matched path imbalance, fringe visibil...
متن کامل