Mass volume measurement in severe head injury: accuracy and feasibility of two pragmatic methods.
نویسندگان
چکیده
OBJECTIVE To assess the clinical feasibility and the accuracy of two pragmatic methods in comparison with a conventional computer based method of measurement of masses from CT. METHODS Nineteen CT scans of 11 patients with severe head injury, showing 34 traumatic lesions, were examined. The volume of every lesion was digitally measured, then a panel of three examiners independently repeated the measurement using the ellipsoid and the Cavalieri method in random order. RESULTS All the lesions were identified by all the readers and the mean volume measured by each examiner differed by less than 1.5 ml. The average reading time for each scan was 4 minutes for the ellipsoid and 7 minutes for the Cavalieri method. The average volume of the lesions was 34.2 (SD 35) ml with the digital system, and 38.4 (SD 41) ml and 34.8 (SD 36) ml for the ellipsoid and the Cavalieri readings respectively. The average difference between the applied technique and the digital system was 0.57 (SD 9.99) ml for the Cavalieri direct estimator and 0.20 (SD 15.48) ml for the ellipsoid method. The 95% confidence interval for this difference fell between -2.75 and 3.89 ml for the Cavalieri, and between -4.94 and 5.35 ml for the ellipsoid method. There were 19 lesions >25 ml; the ellipsoid method identified 16 of them, whereas 17 were classified with the Cavalieri method. When considering individual lesions rather than the average volume, discrepancies were detected with both methods. The ellipsoid method was less precise, especially when extracerebral lesions were measured. CONCLUSIONS Both pragmatic methods are inferior to computer based reading, which is the choice when accurate volume estimation is necessary. However, if a digital volumetric determination of the lesions using a CT computer is not possible, the two pragmatic methods offer an alternative.
منابع مشابه
Feasibility of using Medical Imaging Interaction Toolkit in volumetric studies to accurate diagnosing of vascular emboli by Extended NURBS-based Cardiac-Torso phantom
Introduction: Important complications of venous thromboembolism (VTE) are a longer hospital stay, readmission, recurrence of the emboli, complications of anticoagulant therapy and death in a sever condition. In present study, the volume measurement accuracy of the medical imaging interaction toolkit (MITK) software on determining VTE in computed tomography images was evaluated....
متن کاملDevelopment of a phase change model for volume-of-fluid method in OpenFOAM
In this present study, volume of fluid method in OpenFOAM open source CFD package will be extended to consider phase change phenomena with modified model due to condensation and boiling processes. This model is suitable for the case in which both unsaturated phase and saturated phase are present and for beginning boiling and condensation process needn't initial interface. Both phases (liquid-va...
متن کاملTRAUMATIC INTRAVENTRICULAR HEMORRHAGE IN SEVERE BLUNT HEAD TRAUMA: A ONE YEAR ANALYSIS
ABSTRACT Background: High resolution CT scan has made early diagnosis of intraventricular hemorrhage (IVH) easier. Posttraumatic intraventricular hemorrhage has been reported to a greater extent because of the CT scan. Methods: 904 patients were admitted in the NSICU from March 2001 to March 2002 with severe closed head injury, of those only 31 patients with intraventricular hemorrhage (GCS le...
متن کاملComparing the Persian version properties of Behavioral Pain Scale and Critical Care Pain Observation Tool in patients with head trauma
Introduction: The assessment of pain in critically ill patients requires careful examination, especially in intubated and traumatic head patients due to the impossibility of using verbal pain scales and changes in non-verbal communication due to the type of injury sustained .The purpose of this study was to compare the psychometric properties of the Persian version of Behavioral Pain Scale (BPS...
متن کاملA Mass Conservative Method for Numerical Modeling of Axisymmetric flow
In this paper, the cell-centered finite volume method (CC-FVM) has been presented to simulate the axisymmetric radial flow toward a pumping well. The model is applied to the unstructured triangular grids which allows to simulate inhomogeneous and complex-shaped domains. Due to the non-orthogonality of the irregular grids, the multipoint flux approximation (MPFA) methods are used to discretize t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neurology, neurosurgery, and psychiatry
دوره 68 1 شماره
صفحات -
تاریخ انتشار 2000