Transition metal ion FRET to measure short-range distances at the intracellular surface of the plasma membrane
نویسندگان
چکیده
Biological membranes are complex assemblies of lipids and proteins that serve as platforms for cell signaling. We have developed a novel method for measuring the structure and dynamics of the membrane based on fluorescence resonance energy transfer (FRET). The method marries four technologies: (1) unroofing cells to isolate and access the cytoplasmic leaflet of the plasma membrane; (2) patch-clamp fluorometry (PCF) to measure currents and fluorescence simultaneously from a membrane patch; (3) a synthetic lipid with a metal-chelating head group to decorate the membrane with metal-binding sites; and (4) transition metal ion FRET (tmFRET) to measure short distances between a fluorescent probe and a transition metal ion on the membrane. We applied this method to measure the density and affinity of native and introduced metal-binding sites in the membrane. These experiments pave the way for measuring structural rearrangements of membrane proteins relative to the membrane.
منابع مشابه
Measuring distances between TRPV1 and the plasma membrane using a noncanonical amino acid and transition metal ion FRET
Despite recent advances, the structure and dynamics of membrane proteins in cell membranes remain elusive. We implemented transition metal ion fluorescence resonance energy transfer (tmFRET) to measure distances between sites on the N-terminal ankyrin repeat domains (ARDs) of the pain-transducing ion channel TRPV1 and the intracellular surface of the plasma membrane. To preserve the native cont...
متن کاملDetermination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore
A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...
متن کاملNew rule(r)s for FRET.
In this issue of the Biophysical Journal, Jarecki et al. (1) investigate the possibility of combining two strategies commonly used to measure distances between loci in a number of systems. The first strategy, Förster resonance energy transfer (FRET), is a spectroscopic method based on energy transfer between two fluorescent molecules: upon transferring its excitation energy to an acceptor via a...
متن کاملCytotoxic Effect of \" Glycated Albumin-Transition Metal Ion\" on Rat Hepatocyte Suspension
Background: Combination of glycation and oxidation is associated with diabetes mellitus. The aim of this study was to clarify the effect of glycated proteins in presence of transition metal ions on production of reactive oxygen species (ROS) in rat hepatocyte suspension. Methods: Glycated albumin was prepared by incubation of bovine serum albumin with 100 mM glucose in 0.3 M phosphate buffer a...
متن کاملPotassium-Selective Membrane Sensor Based on Two Recently Synthesized Poly(oxyethylene) Derivatives
Two poly(oxyethylene) derivatives 1.10-bis(2'-benzoic acid)-1,4,7,1-tetradecane (L1) and 1,7-bis(2'-benzoic acid)-1,4,7-trioxaheptane (L2) were used as suitable ionophores for the preparation of potassium-selective PVC-membrane electrodes. The resulting electrodes based on L1 and L2 exhibit linear responses to the activity of K+ ions within the concentration ranges of 3.1<em...
متن کامل