The evaluation of left ventricular function in man. A comparison of methods.
نویسندگان
چکیده
Comparisons of the sensitivities of parameters for assessing left ventricular performance in man were made in 38 patients. The parameters compared were the ejection fraction, ventriculographic contraction patterns, the left ventricular end-diastolic pressure, and the contractile indices including the contractile element velocity at 10 mm Hg (Vce 10) and maximal contractile element velocity (Vmax). The contractile indices were obtained by catheter tip manometry, utilizing developed pressure (DP) to calculate the velocity of contractile element shortening (Vce) from the formula: dp/dt divided by 32 DP. Vce 10 was measured directly and Vmax was derived by linear manual extrapolation of the pressure-velocity plot to 0 mm Hg. Vmax values derived from linear manual extrapolation were compared with values obtained by computer least squares fitting of the Vce and developed pressure data points to single and double exponential equations. The Vce and developed pressure data points fit the single exponential equation better than the double exponential equation but the use of either equation resulted in slightly higher values for Vmax than obtained with linear manual extrapolation. The effect of heart rate on myocardial contractility was eliminated by making comparisons at both a basal and atrial paced rate of 100. Utilizing all methods, 24 patients were identified to have ventricular dysfunction. The contractile indices were significantly less sensitive than any other parameter (P smaller than 0.05) and identified seven patients while the left ventricular end-diastolic pressure, ejection fraction, and presence of asynergy identified 15, 15, and 12 patients, respectively. The use of a common atrial paced rate of 100 did not increase the sensitivity of the contractile indices. Since there was only partial overlapping between parameters in the identification of left ventricular dysfunction, the combination of different parameters was more sensitive than any single parameter alone. It is concluded that several methods are required to identify all patients with left ventricular dysfunction and that the contractile indices are the least sensitive indicator of left ventricular dysfunction.
منابع مشابه
Comparison of Fetal Echocardiography for Fetal Cardiac Structure in Women with Gestational Diabetes Mellitus and Normal Pregnancies
BackgroundIncreased metabolic rate of hyperglycemia in gestational diabetes causes macrosomia, which can also affect the fetal heart. The thickness of the walls of the heart and its function in women with gestational diabetes mellitus (GDM) can change over time before treatment. We aimed to evaluate fetal cardiac structure in terms of ventricular wall thickness and its function in women w...
متن کاملComparison of Cardiac Function in Young Patients with Thalassemia Intermedia and Healthy Individuals Using Echocardiography Method
Background: Cardiac dysfunction due to chronic anemia and hemosiderosis are the major causes of death among patients with thalassemia intermedia. This study was performed to compare the cardiac function in thalassemia intermedia patients with normal subjects by means of echocardiography. Materials and Methods: This was a case-control study performed on 22 patients affected by thalassemia int...
متن کاملEvaluation of Cardiac Function in Patients with Thalassemia Intermedia
Abstract Background Thalassemia intermedia is a variety of beta thalassemia which shows clinical symptoms somewhere between asymptomatic carriers and thalassemia major. Cardiac dysfunctions due to chronic anemia and hemosiderosis are the major causes of death in these patients. The purpose of this study is to evaluate cardiac function in these patients by echocardiography. Materials and Met...
متن کاملNormal Value of Left Ventricular End-Systolic Elastance in Infants and Children
Background: In certain conditions, there is a need for a specific and improved measure of cardiac performance. Routine methods for assessing left ventricular (LV) function are based on image-analysis or right heart monitoring which do not allow evaluation of ventriculo-arterial interaction. Chen et al presented a noninvasive method allowing measurement of end-systolic pressure–volume relation ...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملThe Relation between Left Ventricular Function and Serum Ferritin in Major Β-Thalassemia
Abstract Objective Cardiac dysfunction is a major cause of death in patients with beta thalassemia. In these patients, repeated blood transfusion, ineffective erythropoiesis and increased gastrointestinal iron absorption lead to iron overload in the body and this induced heart failure. Left ventricular ejection fraction was measured in major beta thalassemia (β-Th) patients to detect the rela...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 51 4 شماره
صفحات -
تاریخ انتشار 1975