Magnetic resonance-based attenuation correction for PET/MR hybrid imaging using continuous valued attenuation maps.
نویسندگان
چکیده
OBJECTIVES Attenuation correction of positron emission tomographic (PET) data is critical in providing accurate and quantitative PET volumes. Deriving an attenuation map (μ-map) from magnetic resonance (MR) volumes is a challenge in PET/MR hybrid imaging. The difficulty lies in differentiating cortical bone from air from standard MR sequences because both these classes yield little to no MR signal and thus shows no distinguishable information. The objective of this contribution is 2-fold: (1) to generate and evaluate a continuous valued computed tomography (CT)-like attenuation map (μ-map) with continuous density values from dedicated MR sequences and (2) to compare its PET quantification accuracy with respect to a CT-based attenuation map as the criterion standard and other segmentation-based attenuation maps for studies of the head. MATERIALS AND METHODS Three-dimensional Dixon-volume interpolated breath-hold examination and ultrashort echo time sequences were acquired for each patient on a Siemens 3-T Biograph mMR PET/MR hybrid system and the corresponding patient CT on a Siemens Biograph 64. A pseudo-CT training was done using the epsilon-insensitive support vector regression ([Latin Small Letter Open E]-SVR) technique on 5 patients who had CT/MR/PET triplets, and the generated model was evaluated on 5 additional patients who were not included in the training process. Four μ-maps were compared, and 3 of them derived from CT: scaled CT (μ-map CT), 3-class segmented CT without cortical bone (μ-map no bone), 4-class segmented CT with cortical bone (μ-map bone), and 1 from MR sequences via [Latin Small Letter Open E]-SVR technique previously mentioned (ie, MR predicted [μ-map MR]). Positron emission tomographic volumes with each of the previously mentioned μ-maps were reconstructed, and relative difference images were calculated with respect to μ-map CT as the criterion standard. RESULTS For PET quantification, the proposed method yields a mean (SD) absolute error of 2.40% (3.69%) and 2.16% (1.77%) for the complete brain and the regions close to the cortical bone, respectively. In contrast, PET using μ-map no bone yielded 10.15% (3.31%) and 11.03 (2.26%) for the same, although PET using μ-map bone resulted in errors of 3.96% (3.71%) and 4.22% (3.91%). Furthermore, it is shown that the model can be extended to predict pseudo-CTs for other anatomical regions on the basis of only MR information. CONCLUSIONS In this study, the generation of continuous valued attenuation maps from MR sequences is demonstrated and its effect on PET quantification is evaluated in comparison with segmentation-based μ-maps. A less-than-2-minute acquisition time makes the proposed approach promising for a clinical application for studies of the head. However, further experiments are required to validate and evaluate this technique for attenuation correction in other regions of the body.
منابع مشابه
Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...
متن کاملHybrid PET/MR imaging: an algorithm to reduce metal artifacts from dental implants in Dixon-based attenuation map generation using a multiacquisition variable-resonance image combination sequence.
UNLABELLED It was the aim of this study to implement an algorithm modifying Dixon-based MR imaging datasets for attenuation correction in hybrid PET/MR imaging with a multiacquisition variable resonance image combination (MAVRIC) sequence to reduce metal artifacts. METHODS After ethics approval, in 8 oncologic patients with dental implants data were acquired in a trimodality setup with PET/CT...
متن کاملVision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities.
Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing novel strategies for deriving accurate attenuation maps with the aim to improve t...
متن کاملImpact of MR based attenuation correction on neurological PET studies
Hybrid positron emission tomography (PET) and magnetic resonance (MR) scanners have become a reality in recent years with the benefits of reduced radiation exposure, reduction of imaging time, and potential advantages in quantification. Appropriate attenuation correction remains a challenge. Biases in PET activity measurements were demonstrated using the current MR based attenuation correction ...
متن کاملNew Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor
Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...