Coagulation activity and emboli counts in patients with prosthetic cardiac valves.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The underlying embolic material detected by transcranial Doppler ultrasound in patients with prosthetic heart valves remains unknown. We undertook this study to evaluate the relation between the number of Doppler emboli signals and the activity of the coagulation system. METHODS Patients with various types of prosthetic valves (n = 120) and patients in atrial fibrillation (n = 20) were monitored for 30 minutes using transcranial Doppler with a 2-MHz probe. The plasma concentrations of cross-linked D-dimer, antithrombin-III, and thrombin-antithrombin III complex were measured. RESULTS No correlation between the levels of any of the hematologic parameters and the number of emboli was demonstrated in the studied groups. The D-dimer levels were significantly higher in patients with mechanical prosthetic valves with an international normalized ratio under 2.0 compared with those with an international normalized ratio between 2 and 3.5 or above 3.5, and in patients with Medtronic-Hall versus Björk-Shiley or Carpentier-Edwards valve prostheses. CONCLUSIONS The lack of correlation between the activity of the coagulation system and the number of Doppler emboli in patients with prosthetic valves suggests that the underlying embolic material in these patients is not thrombotic. Our results also suggest that an increase of the anticoagulation intensity to an international normalized ratio above 3.5 does not result in a further decrease of the activity of the unstimulated coagulation system in patients with mechanical prosthetic valves.
منابع مشابه
Evaluation of transesophageal echocardiography in detecting cardiac sources of emboli in ischemic stroke patients
Background: Embolus is one of the causes of ischemic stroke that can be due to cardiac sources such as valvular heart diseases and atrial fibrillation and atheroma of the aorta. Transesophageal echocardiography (TEE) is superior in identifying potential cardiac sources of emboli. Due to insufficient data on TEE findings in ischemic stroke in Iran, the present study was done to evaluate TEE in...
متن کاملPregnancy Outcome with Intracytoplasmic Sperm Injection Method in a Woman with Prosthetic Heart Valves
There is an increased risk of thromboembolism, anticoagulant-related hemorrhage, fetal-wastage and congestive cardiac failure in pregnant women with mechanical heart valves. In order to have a good outcome, the care of such patients must necessarily be multidisciplinary and in a well- equipped centre with adequate support services .One such patient who had mechanical mitral and aortic valves re...
متن کاملQuantification of ultrasound emboli signals in patients with cardiac and carotid disease.
BACKGROUND AND PURPOSE The use of Doppler ultrasound to detect arterial emboli has major implications for the classification and treatment of stroke. Experimental studies indicate that embolic materials produce different ultrasound signals, depending on their acoustic properties. To examine the possibility of characterizing emboli of different sources in the clinical setting, we compared the em...
متن کاملDevelopment of antithrombin antibodies following surgery in patients with prosthetic cardiac valves.
Although antibody inhibitors directed against blood coagulation factors are well known, antibody inhibitors directed against thrombin are rare. We describe three postsurgical patients with prosthetic cardiac valves who developed serum autoantibodies reactive with human and bovine thrombin, as demonstrated by coagulation studies and immunoblotting. Despite marked prolongation of the thrombin tim...
متن کاملDifferentiation between gaseous and formed embolic materials in vivo. Application in prosthetic heart valve patients.
BACKGROUND AND PURPOSE Doppler emboli detection is an established technique, but the nature of the underlying embolic material remains unclear. The intensity and spectral distribution of emboli signals could help to distinguish between signals arising from formed and gaseous emboli. We undertook this study to develop and evaluate a differentiation algorithm based on the spectral characteristics...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 25 6 شماره
صفحات -
تاریخ انتشار 1994