Lung deposition of budesonide from a pressurized metered-dose inhaler attached to a spacer.

نویسندگان

  • L Thorsson
  • S Edsbäcker
چکیده

The absolute systemic availability and pulmonary deposition of budesonide inhaled from a pressurized metered-dose inhaler (pMDI) attached to a Nebuhaler spacer was determined in 15 healthy subjects. The study was of an open cross-over design. Each subject randomly received three single doses of budesonide on separate days: 0.5 mg given intravenously and 1.0 mg (0.2 mg x 5) by inhalation from a pMDI with a Nebuhaler, with or without concomitant oral charcoal intake to prevent gastrointestinal absorption. Charcoal intake did not significantly affect the systemic availability or deposition of budesonide. The systemic availability was 36+/-14% (metered dose, mean+/-SD) with charcoal and 35+/-10% without. The pulmonary deposition was 36+/-14% with charcoal and 34+/-11% without. Erroneous administration, in which the canister was shaken only before the first of the five actuations, halved the systemic availability. In conclusion, the pulmonary deposition of budesonide from a pressurized metered-dose inhaler with Nebuhaler is high under optimum conditions. The small discrepancy between the systemic availability and pulmonary deposition indicates that the contribution from deposition in the oropharynx and subsequent absorption from the gastrointestinal tract is negligible. The marked reduction in the systemic availability of budesonide with the unshaken canisters confirms that the performance of a pressurized metered-dose inhaler is very much dependent on proper handling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lung deposition of budesonide from Turbuhaler is twice that from a pressurized metered-dose inhaler (P-MDI)

Therefore, any differences in lung deposition need to be supported by clinical data to determine whether they are clinically relevant. Indeed, there are data which show no difference, in terms of improvements in lung function, between the MDI and Turbuhaler in multiple-dose studies with ipatropium bromide [3], terbutaline [4, 5] and budesonide [6] as well as single-dose and cumulative dose stud...

متن کامل

Lung deposition of budesonide from Turbuhaler is twice that from a pressurized metered-dose inhaler P-MDI.

The pulmonary and systemic availability of budesonide after inhalation from a dry powder inhaler, Turbuhaler, and from a pressurized metered-dose inhaler (P-MDI) were compared in healthy volunteers. Two different methods were used to assess pulmonary availability: 1) calculated from the systemic availability corrected for an oral availability of 13% (n = 24); and 2) after blocking of gastrointe...

متن کامل

Delivery of propellant soluble drug from a metered dose inhaler.

The deposition of particulate suspensions delivered from a metered dose inhaler has been investigated extensively. The distribution of propellant, delivered from a metered dose inhaler, was studied by radiolabelling it with technetium-99m hexamethylpropyleneamine oxime. Andersen sampler measurements indicated that half of the dose was associated with particles in the size range 0.5-5 microns di...

متن کامل

Facemasks and aerosol delivery in vivo.

It has been shown in vitro that even a small air leak in the facemask can drastically reduce the efficiency of drug delivery. In addition, it has been shown that drug deposition on the face does significantly add to overall drug loss and has the potential of local side effects. The aim of this study is therefore to verify these findings in vivo. Eight asymptomatic recurrently wheezy children, a...

متن کامل

Computational analyses of a pressurized metered dose inhaler and a new drug-aerosol targeting methodology.

The popular pressurized metered dose inhaler (pMDI), especially for asthma treatment, has undergone various changes in terms of propellant use and valve design. Most significant are the choice of hydrofluoroalkane-134a (HFA-134a) as a new propellant (rather than chlorofluorocarbon, CFC), a smaller exit nozzle diameter and attachment of a spacer in order to reduce ultimately droplet size and spr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 12 6  شماره 

صفحات  -

تاریخ انتشار 1998