Diagnostic performance of low-dose CT for the detection of urolithiasis: a meta-analysis.

نویسندگان

  • Tilo Niemann
  • Thilo Kollmann
  • Georg Bongartz
چکیده

OBJECTIVE The objective of our study was to perform a meta-analysis to evaluate the diagnostic performance of low-dose CT for the diagnosis of urolithiasis (seven studies, 1,061 patients). MATERIALS AND METHODS The medical literature from 1995 to 2007 was searched using PubMed, Medline, and Cochrane Library databases for articles on studies that used low-dose CT (< 3 mSv dose applied for the entire CT examination) as a diagnostic test for the detection of urolithiasis. Prospective and retrospective studies were included if they separately reported the rate of true-positive, true-negative, false-positive, and false-negative diagnoses of urolithiasis from low-dose CT compared with the positive and negative rates of normal-dose CT or a combination of diagnostic tests. Two readers assessed the quality of the studies. RESULTS The pooled sensitivity and specificity of low-dose CT for the diagnosis of urolithiasis were 0.966 (95% CI, 0.950-0.978) and 0.949 (95% CI, 0.920-0.970), respectively. CONCLUSION The results of this meta-analysis suggest that a low-dose CT protocol can be used as the initial imaging technique in the workup of patients with suspected urolithiasis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Molecular imaging approaches in the diagnosis of breast cancer: A systematic review and meta-analysis

Introduction:The accuracy of positron emission tomography with computed tomography (PET/CT), positron emission mammography (PEM), and breast specific-gamma imaging (BSGI) in diagnosing breast cancer has never been systematically assessed, the present systematic review was aimed to address this issue.  Methods:PubMed, Scopus and EMBASE were searched for st...

متن کامل

Application of personal non-lead nano-composite shields for radiation protection in diagnostic radiology: a systematic review and meta-analysis

composites with micro- and nano-metal fillers has attracted the attention of researchers for radiation shielding applications. Lead toxicity and heaviness have oriented extensive research toward the use of non-lead composite shields. The present study aimed to systematically review the efficiency of the composite shields of various micro- and nano-sized materials as composite shields have been ...

متن کامل

Diagnostic Accuracy of CT Scan for Detection of Cervical Lymph Node Metastasis in Oral Squamous Cell Carcinoma in Comparison with Histopathological Analysis After Neck Dissection

Objectives: Presence/absence of cervical lymph node metastasis plays a critical role in prognosis and survival of patients with oral squamous cell carcinoma (SCC). This study was designed to assess the diagnostic accuracy of computed tomography (CT) scan for detection of cervical lymph node metastasis in oral SCC in comparison with histopathological analysis after neck dissection Methods: In...

متن کامل

The Value of Urinalysis in Detection of Abdominal Organ Injuries in Children with Hematuria Following Blunt Abdominal Trauma; A Diagnostic Study

Background Currently, almost all patients with probable abdominal injury undergo urinalysis in emergency department (ED). The present survey was conducted with the aim of assessing the diagnostic values of urinalysis compare with abdominal computed tomography (CT) scan with contrast for predicting possible intra-abdominal injuries in children affected by blunt trauma. Materials and Methods: The...

متن کامل

Diagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey

Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 191 2  شماره 

صفحات  -

تاریخ انتشار 2008