Partial Discharge Testing of Defective Three-phase Pilc Cable under Rated Conditions
نویسندگان
چکیده
The ability to accurately monitor the health of power distribution plant is a very attractive prospect for utility companies. This capability would provide a system that engineers could use to assess the real-time state of the network. Analysis of the data produced could allow for more informed decisions to be made in the areas of asset replacement and maintenance scheduling amongst others. It is widely accepted that partial discharge activity is linked with the electrical ageing/degradation of high voltage equipment. Work at Southampton is focused on obtaining a better understanding of the characteristics and trends of partial discharge events associated with medium voltage cables under, 'real life' conditions. An experiment has been developed that allows for service conditions to be applied to defective paper insulated lead covered cable samples. The samples under investigation were exposed to mechanical damage designed to replicate typical problems found on an active circuit. Partial discharge measurement was undertaken during the stressing process.
منابع مشابه
Power Cable Joint Model: Based on Lumped Components and Cascaded Transmission Line Approach
Abstract: Models in high frequency range for underground power cable connections are essential for the interpretation of partial discharge (PD) signals arising e.g. diagnostic techniques. This paper focuses on modeling of power cable joints. A lumped parameter odel and a cascaded transmission line model are proposed based on scattering parameters (S -parameters) measurement on a 10 kV oil-fille...
متن کاملEffect of Atmospheric Conditions on Cable Termination to Switchgear
ABSTRACT: An intensive research work is carried out to determine the effect of humidity and contamination on cable termination and it’s aging. In this paper, the effect of atmospheric conditions on cable termination has been investigated by measurement of discharge inception voltage, discharge magnitude, dielectric loss and capacitance of each phase of cable. The three possible conditions i.e n...
متن کاملInnovative approach to strata reinforcement in coal mines with reference to evaluation cable bolts shear strength
There is an increasing need to determine accurately the strength properties of tendons for an effective ground control on mines and underground structures as well as on modelling simulations. The strength properties of cables, used as cable bolts, have been evaluated mainly by their ultimate tensile strength, as this kind of test can be carried out in the field as well as in the laboratory. Onl...
متن کاملPartial Discharges in Low-Voltage Cables
Testing of high voltage apparatus for partial discharges has long been recognized as an important part of quality control for these devices. Recently, interest has been focused on methods for testing low voltage cables to determine their integrity under adverse operating conditions such as a loss of coolant accident. A new method, utilizing partial discharges, is presented which has the potenti...
متن کاملElectric Field Investigation in MV PILC Cables with Void Defect
Abstract—Worldwide, most PILC MV underground cables in use are approaching the end of their design life; hence, failures are likely to increase. This paper studies the electric field and potential distributions within the PILC insulted cable containing common void-defect. The finite element model of the performance of the belted PILC MV underground cable is presented. The variation of the elect...
متن کامل